These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Predictors of Permanent Pacemaker Implantations and New-Onset Conduction Abnormalities With the SAPIEN 3 Balloon-Expandable Transcatheter Heart Valve.
    Author: Husser O, Pellegrini C, Kessler T, Burgdorf C, Thaller H, Mayr NP, Kasel AM, Kastrati A, Schunkert H, Hengstenberg C.
    Journal: JACC Cardiovasc Interv; 2016 Feb 08; 9(3):244-254. PubMed ID: 26847116.
    Abstract:
    OBJECTIVES: This study investigates the influence of implantation depth and prosthesis oversizing on conduction abnormalities (CA) and permanent pacemaker implantation (PPI) after SAPIEN 3 (Edwards Lifesciences, Irvine, California) implantation. BACKGROUND: CA and PPIs are frequent complications after transcatheter aortic valve replacement with a next-generation balloon-expandable transcatheter heart valve (SAPIEN 3). The potential underlying mechanisms are incompletely understood. METHODS: Of 244 patients treated with SAPIEN 3,208 without a previous pacemaker and 184 without baseline CA were analyzed. We assessed the association of angiographic implantation depth (% of frame height below the annulus) and degree of oversizing with PPI and CA. RESULTS: New PPI and new or worsened CA or PPI occurred in 16% (34 of 208) and 31% (57 of 184), respectively. Patients requiring PPI had a higher prevalence of atrial fibrillation (44% vs. 24%; p = 0.017), complete right bundle branch block (27% vs. 5%; p = 0.001), and bradycardia (<60 beats/min, 38% vs. 21%; p = 0.034). In patients with new CA or PPI, implantation depth was lower (at septal side: 29 ± 8% vs. 25 ± 7%; p = 0.003), and rate of oversizing was higher (19% [11 of 57] vs. 6% [8 of 126]; p = 0.007). Independent predictors of new or worsened CA or PPI were implantation depth at septal side (odds ratio [OR]: 1.063 [95% confidence interval (CI): 1.017 to 1.110]; p = 0.006 per % of frame below the aortic annulus), oversizing (OR: 3.489 [95% CI: 1.236 to 9.848]; p = 0.018), and QRS duration (OR: 1.033 [95% CI: 1.011 to 1.056]; p = 0.003 per ms). CONCLUSIONS: Implantation depth and prosthesis oversizing were associated with a higher rate of new CA or PPI using the SAPIEN 3. Thus, avoidance of deep implantation and extreme oversizing may reduce these complications.
    [Abstract] [Full Text] [Related] [New Search]