These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: ASGE Technology Committee systematic review and meta-analysis assessing the ASGE Preservation and Incorporation of Valuable Endoscopic Innovations thresholds for adopting real-time imaging-assisted endoscopic targeted biopsy during endoscopic surveillance of Barrett's esophagus. Author: ASGE Technology Committee, Thosani N, Abu Dayyeh BK, Sharma P, Aslanian HR, Enestvedt BK, Komanduri S, Manfredi M, Navaneethan U, Maple JT, Pannala R, Parsi MA, Smith ZL, Sullivan SA, Banerjee S. Journal: Gastrointest Endosc; 2016 Apr; 83(4):684-98.e7. PubMed ID: 26874597. Abstract: BACKGROUND AND AIMS: Endoscopic real-time imaging of Barrett's esophagus (BE) with advanced imaging technologies enables targeted biopsies and may eliminate the need for random biopsies to detect dysplasia during endoscopic surveillance of BE. This systematic review and meta-analysis was performed by the American Society for Gastrointestinal Endoscopy (ASGE) Technology Committee to specifically assess whether acceptable performance thresholds outlined by the ASGE Preservation and Incorporation of Valuable Endoscopic Innovations (PIVI) document for clinical adoption of these technologies have been met. METHODS: We conducted meta-analyses calculating the pooled sensitivity, negative predictive value (NPV), and specificity for chromoendoscopy by using acetic acid and methylene blue, electronic chromoendoscopy by using narrow-band imaging, and confocal laser endomicroscopy (CLE) for the detection of dysplasia. Random effects meta-analysis models were used. Statistical heterogeneity was evaluated by means of I(2) statistics. RESULTS: The pooled sensitivity, NPV, and specificity for acetic acid chromoendoscopy were 96.6% (95% confidence interval [CI], 95-98), 98.3% (95% CI, 94.8-99.4), and 84.6% (95% CI, 68.5-93.2), respectively. The pooled sensitivity, NPV, and specificity for electronic chromoendoscopy by using narrow-band imaging were 94.2% (95% CI, 82.6-98.2), 97.5% (95% CI, 95.1-98.7), and 94.4% (95% CI, 80.5-98.6), respectively. The pooled sensitivity, NPV, and specificity for endoscope-based CLE were 90.4% (95% CI, 71.9-97.2), 98.3% (95% CI, 94.2-99.5), and 92.7% (95% CI, 87-96), respectively. CONCLUSIONS: Our meta-analysis indicates that targeted biopsies with acetic acid chromoendoscopy, electronic chromoendoscopy by using narrow-band imaging, and endoscope-based CLE meet the thresholds set by the ASGE PIVI, at least when performed by endoscopists with expertise in advanced imaging techniques. The ASGE Technology Committee therefore endorses using these advanced imaging modalities to guide targeted biopsies for the detection of dysplasia during surveillance of patients with previously nondysplastic BE, thereby replacing the currently used random biopsy protocols.[Abstract] [Full Text] [Related] [New Search]