These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: [EFFECTIVENESS OF UC ULTRA-CONGRUENT ROTATING PLATFORM PROSTHESIS IN TREATMENT OF KNEE OSTEOARTHRITIS].
    Author: Huo S, Wang H, Zhou C, Chen Q, Dong L, Tang H, Guo C, Chen J, Liu Y.
    Journal: Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2015 Nov; 29(11):1342-7. PubMed ID: 26875264.
    Abstract:
    OBJECTIVE: To explore the effectiveness of UC ultra-congruent rotating platform prosthesis in the treatment of knee osteoarthritis by comparing with fixed-bearing implant. METHODS: The clinical data were retrospectively analyzed, from 98 patients (98 knees) with knee osteoarthritis undergoing primary total knee arthroplasty between January 2011 and December 2012. The UC ultra-congruent rotating platform prosthesis was used in 56 cases (mobile-bearing group) and fixed-bearing implant was used in 42 cases (fixed-bearing group). There was no significant difference in gender, age, side, weight, disease duration, grading of arthritis, the number of varus and valgus malformation, preoperative range of motion of the knee, the Knee Society Score (KSS) score, the visual analogue scale (VAS) score, femorotibial angle, tibial angle, and articular surface angle between 2 groups (P > 0.05). The operation time (including anesthetic time), intraoperative blood loss, hospitalization time, total hospitalization expenses, postoperative range of motion of the knee, the KSS score, and the VAS score were compared. The femorotibial angle, tibial angle, and articular surface angle were measured on the basis of anteroposterior and lateral X-ray films, and prosthesis loosening was observed. RESULTS: There was no significant difference in the operation time, intraoperative blood loss, and hospitalization time between 2 groups (P > 0.05), while the total hospitalization expenses of fixed-bearing group were significantly lower than those of the mobile-bearing group (t = 8.506, P = 0.000). The patients were followed up 16-30 months in the mobile-bearing group, and for 16-38 months in the fixed-bearing group. Postoperative complications occurred in 3 cases (7.14%) of the fixed-bearing group (1 case of fat liquefaction of incision, 1 case of joint stiff, and 1 case of anterior knee pain), and in 3 cases (5.36%) of the mobile-bearing group (1 case of delayed wound healing, and 2 cases of anterior knee pain); there was no significant difference in the complication rate between 2 groups (χ2 = 0.133, P = 0.516). At last follow-up, the KSS score, VAS score, range of motion of the knee, femorotibial angle, tibial angle, and articular surface angle were superior significantly to those before operation in both groups (P < 0.05), but no significant difference was found between 2 groups (P > 0.05). No radiographic signs of radiolucent line, prosthetic dislocation, patellar dislocation, prosthetic loosening, and fracture was found. CONCLUSION: UC ultra-congruent rotating platform prosthesis in the treatment of knee osteoarthritis can effectively improve the knee joint function and relief pain, which has the same short-term effectiveness in fixed bearing implant.
    [Abstract] [Full Text] [Related] [New Search]