These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: A pilot study of upper airway management using a remote-controlled artificial muscle device during propofol anesthesia. Author: Kurata S, Sanuki T, Okayasu I, Kawai M, Moromugi S, Ayuse T. Journal: J Clin Anesth; 2016 Mar; 29():75-82. PubMed ID: 26897452. Abstract: STUDY OBJECTIVE: To test the hypothesis that the jaw closure using a pneumatic actuator device affect airway collapsibility and resistance during propofol anesthesia. DESIGN: Prospective, randomized study. SETTING: University-affiliated hospital. PATIENTS: Six male subjects were included in the present study. INTERVENTION: We used pressure-flow relationships to evaluate critical closing pressure (PCRIT) and upper airway resistance in different conditions of body and head position. Anesthesia was induced and maintained with a propofol infusion, targeting a constant blood concentration of 1.5 to 2.0μg/mL to establish an adequate depth of anesthesia, with patients breathing spontaneously through a nasal mask. An air-inflatable pneumatic actuator was used to achieve jaw closure. Nasal mask pressure was intermittently reduced to evaluate upper airway collapsibility (passive PCRIT) and upstream resistance under 4 different conditions: (1) neutral occlusion at 0-cm head elevation (baseline), (2) jaw closure at 0-cm head elevation, (3) neutral occlusion at 6-cm head elevation, and (4) jaw closure at 6-cm head elevation. PCRIT and upstream resistance under each condition were compared using 1-way analysis of variance. P<.05 was considered significant. MEASUREMENTS: The pressure and inspiratory flow at the subjects' nose mask were recorded. Polysomonographic parameters (electroencephalograms, electrooculograms, submental electromyograms, and plethysmogram) were also recorded. MAIN RESULTS: The combination of 6-cm head elevation with jaw closure using the pneumatic actuator decreased upper airway collapsibility (PCRIT≈-3.0 cm H2O) compared to the baseline position (PCRIT≈-1.2 cm H2O; P=.0003). CONCLUSION: We demonstrated that jaw closure using an air-inflatable pneumatic actuator device can produce substantial decreases in upper airway collapsibility and maintain upper airway patency during propofol anesthesia.[Abstract] [Full Text] [Related] [New Search]