  • Title: Systematic Comparison of Reduced Tube Current Protocols for High-pitch and Standard-pitch Pulmonary CT Angiography in a Large Single-center Population.
    Author: Bucher AM, Kerl MJ, Albrecht MH, Beeres M, Ackermann H, Wichmann JL, Vogl TJ, Bauer RW, Lehnert T.
    Journal: Acad Radiol; 2016 May; 23(5):619-27. PubMed ID: 26905455.
    Abstract:
    RATIONALE AND OBJECTIVES: Benefits of iterative reconstruction (IR) algorithms combined with dose-reduction techniques have been shown at computed tomography pulmonary angiography (CTPA) in several medium to small patient collectives. In this study, we performed a systematic comparison of image quality to combinations of reduced tube current (RC) and IR for both standard-pitch (SP) single-source and high-pitch (HP) dual-source CTPA in a large, single-center population. MATERIALS AND METHODS: Three hundred eighty-two consecutive patients (October 2010 through December 2012) received clinically indicated CTPA with one of four consecutively changed protocols: (1) HPSC: 180 mAs, weighted filtered back projection, pitch = 3; (2) HPRC: 90 mAs, IR, pitch = 3; (3) SPSC: 180 mAs, weighted filtered back projection, pitch = 1.2; and (4) HPRC: 90 mAs, IR, pitch = 1.2. Tube potential was 100 kV. Vascular attenuation and standardized signal-to-noise ratio (sSNR) were measured in the pulmonary trunk (sSNRPT) and on segmental artery level (sSNRS1, sSNRS10). Dose-length-product was recorded per series. Two independent investigators rated image quality. Kolmogorov-Smirnov test, Kruskal-Wallis test, and kappa statistics were used for statistical analysis. Median values are presented per group. RESULTS: Image quality was consistent between all groups (observer 1: P = 0.118; observer 2: P = 0.122). Inter-reader consistency was very good (κ = 0.866, P < 0.001). Dose-length-product was significantly reduced in HP and RC groups (P < 0.001 for each; SPSC: 139.5 mGycm; HPRC: 92 mGycm; SPSC: 211 mGycm; HPRC: 137 mGycm). sSNR was comparable (sSNRPT overall: P = 0.052; sSNRS1 overall: P = 0.161; and sSNRS10 overall: P = 0.259). CONCLUSIONS: Substantial dose reduction can be within a routine clinical setting without quantifiable loss of image quality either by HP pulmonary angiography or by a combination of IR and RC in either HP or SP acquisition.
    [Abstract] [Full Text] [Related] [New Search]