These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Feasibility of Dual Flip Angle-Based Fast 3-Dimensional T1 Mapping for Delayed Gadolinium-Enhanced Magnetic Resonance Imaging of Cartilage of the Knee: A Histologically Controlled Study. Author: Zong M, Yan C, Lu L, Shi HB, Yu RB. Journal: J Comput Assist Tomogr; 2016; 40(3):442-6. PubMed ID: 26938692. Abstract: OBJECTIVE: The aim of the study was to validate dual-flip angle-based fast 3-dimensional (3D) T1 mapping for delayed gadolinium-enhanced magnetic resonance imaging (MRI) of cartilage (dGEMRIC) by means of histological analyses in the assessment of the cartilage of the knee in a porcine model. METHODS: A total of 15 mini pigs were included in this study. The left knee anterior cruciate ligaments of all mini pigs were transected. The mini pigs were divided into 3 groups postoperatively, with 5 pigs randomly assigned to 1 group. Dual-flip angle-based fast T1 mapping for dGEMRIC was obtained in the sagittal planes at 0 week (group 1), 3 weeks (group 2), and 6 weeks (group 3) after operation, using an 8-channel knee coil. Magnetic resonance imaging was performed at 3T with dual-flip angle-based fast 3D T1 mapping sequence for morphological cartilage assessment of dGEMRIC T1 values. After MRI analysis, histological and biochemical composition (water, collagen, and glycosaminoglycan [GAG]) of the knee cartilage in the medial femoral condyle was quantified ex vivo. RESULTS: The T1 values obtained by the dual-flip angle-based fast 3D T1 mapping were positively correlated with the glycosaminoglycan content (r = 0.85; P < 0.05). The values had no significant correlation with the collagen content. The dGEMRIC-T1 values obtained by this method showed the medial femoral condyle cartilage in the anterior cruciate ligament-transected knee after transection decreased with time (P < 0.05). Histological sections of cartilage damage were correlated with MRI data. CONCLUSIONS: This study demonstrated the reliability of using dual-flip angle-based fast T1 mapping for dGEMRIC for the biochemical assessment of early cartilage degeneration. This technique is a powerful tool for researchers and clinicians to acquire sufficient resolution data within a reasonable scan time.[Abstract] [Full Text] [Related] [New Search]