These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: [Long-term outcome after cardioverter-defibrillator implantation in patients with Brugada syndrome].
    Author: Binbin Y, Jingping L, Bing Y, Minglong C, Jiangang Z, Kejiang C, Qijun S.
    Journal: Zhonghua Xin Xue Guan Bing Za Zhi; 2015 Aug; 43(8):690-4. PubMed ID: 26955725.
    Abstract:
    OBJECTIVE: To observe the long-term outcome of implantable cardioverter-defibrillator (ICD) implantation in Brugada syndrome patients and to explore how to reduce the frequency of ICD nappropriate schocks. METHODS: This study included 14 symptomatic patients (mean age (44.3 ± 8.3) years old; all males) with Brugada syndrome implanted with ICD in our hospital between 1998 and 2012, and these patients were followed up routinely every 6 months. The initial ICD parameters were set according o conventional experience. The ventricular tachycardia (VT) zone was programmed to ventricular rate 150-188 bpm/cycle length (CL) 400-320 ms and the ventricular fibrillation (VF) zone was programmed to ventricular rate ≥ 188 bpm/CL ≤ 320 ms. The total events were recorded by ICD. The ICD parameters revision was made by electrophysiological (EP) experts in case of inappropriate shocks. RESULTS: Patients were followed up for mean (43.0 ± 28.3) months. A total of 297 VF/VT events were recorded by ICD. Electrophysiological experts found that 90% (178/198) episodes were true VF ( CL 130-250 ms) among of 198 VF episodes and 147 VF episodes were terminated by one shock and 21 VF events were terminated by two or more shocks, and the rest 10 VF terminated spontaneously. Only 9% (9/99) VT events were true VT (CL 320-360 ms) among of 99 VT episodes. Eight VT episodes were converted by antitachycardia pacing therapy (ATP) and the other one terminated spontaneously. The rest 90 VT episodes (91%) were supraventricular arrhythmias (SVT, CL 340-390 ms). About 90% inappropriate shocks can be reduced by Wavelet discrimination function and optimal programming (VF zone ventricular rate ≥ 222 bpm/CL ≤ 270 ms and/or VT zone ventricular rate 167-222 bpm/CL 270-360 ms ) according to the characteristics of arrhythmia of individual patient. CONCLUSION: ICD can effectively prevent sudden cardiac death and syncope in high-risk patients with Brugada syndrome. The most common complication is inappropriate shock due to SVT. Optimal ICD programming with Wavelet discrimination function can effectively reduce the frequency of inappropriate shock rate.
    [Abstract] [Full Text] [Related] [New Search]