These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Left ventricular mechanics assessed by two-dimensional echocardiography and cardiac magnetic resonance imaging: comparison of high-resolution speckle tracking and feature tracking. Author: Aurich M, Keller M, Greiner S, Steen H, Aus dem Siepen F, Riffel J, Katus HA, Buss SJ, Mereles D. Journal: Eur Heart J Cardiovasc Imaging; 2016 Dec; 17(12):1370-1378. PubMed ID: 27013249. Abstract: AIMS: Assessment of left ventricular (LV) systolic function plays a central role in cardiac imaging. Calculation of ejection fraction (EF) is the current method of choice; however, its limited intermodal comparability represents a major drawback. The assessment of myocardial mechanics by strain imaging may better reflect the complex myocardial contractility. We aimed to evaluate different methods for quantification of LV strain on global and regional levels with a focus on the new non-proprietary feature tracking (FT) algorithm. METHODS AND RESULTS: Measurements of LV deformation were performed by means of high-resolution two-dimensional (2D) speckle tracking echocardiography (STE) and compared with values obtained by 2D feature tracking echocardiography (FT-E) and feature tracking cardiac magnetic resonance imaging (FT-CMR). Assessments with echocardiography started within 30 min after CMR examination to minimize time-dependent variations in myocardial function. Forty-seven patients were included. Assessments by STE were -15.7 ± 5.0% for global longitudinal strain (GLS), -14.6 ± 4.5% for global circumferential strain (GCS), and 21.6 ± 13.3% for global radial strain (GRS), while values obtained with FT-E were -13.1 ± 4.0, -13.6 ± 4.0, 20.3 ± 9.5, and with FT-CMR -15.0 ± 4.0, -16.9 ± 5.4, and 35.0 ± 10.8, respectively. Linear regression and the Bland-Altman analysis showed the best intramodal association for STE GLS and FT-E GLS (r = 0.88, bias = -2.7%, LOA = ±4.7%). The correlation for GCS and GRS was weaker, and for regional strain was poor. In contrast to EF, GLS showed a better intermodal correlation between echocardiography and CMR (r = 0.81 by speckle tracking, r = 0.8 by FT, and r = 0.78 by EF). CONCLUSION: In our study, measurement of global longitudinal LV strain using the new FT algorithm with CMR and echocardiography was comparable with measurements obtained by high-resolution STE. Compared with echocardiographic EF determination, FT-E GLS shows a better reproducibility and a better intermodal agreement with CMR, representing a fair non-proprietary solution for this assessment. CLINICAL TRIAL REGISTRATION: clinicaltrials.gov. Unique identifier: NCT01275963.[Abstract] [Full Text] [Related] [New Search]