Title: Development of a Hydrogen Sulfide End-of-Service-Life Indicator for Respirator Cartridges Using Cobinamide. Author: Greenawald LA, Boss GR, Reeder A, Bell S. Journal: Sens Actuators B Chem; 2016 Jul; 230():658-666. PubMed ID: 27022206. Abstract: An inexpensive paper-based sensor was developed for detecting low ppm concentrations of hydrogen sulfide gas. A piece of filter paper containing aquohydroxocobinamide [OH(H2O)Cbi] was placed on the end of a bifurcated optical fiber, and the reflectance spectrum of the OH(H2O)Cbi was monitored during exposure to 10.0 ppm hydrogen sulfide gas (NIOSH recommended exposure limit). Reaction of sulfide (HS-) yielded an increase in reflectance from 400-450 nm, and decrease from 470-550 nm. Spectral changes were monitored as a function of time at 25, 50, and 85% relative humidity. Spectral shifts at high-er humidity suggested reduction of the Cbi(III) compound. The sensor was used to detect hydrogen sulfide breakthrough from respirator carbon beds and results correlated well with a standard electrochemical detector. The simple paper-based sensor could provide a real-time end-of-service-life alert for hydrogen sulfide gas.[Abstract] [Full Text] [Related] [New Search]