These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Clinical value of dual-energy spectral imaging with adaptive statistical iterative reconstruction for reducing contrast medium dose in CT portal venography: in comparison with standard 120-kVp imaging protocol.
    Author: Ma CL, Chen XX, Lei YX, Zhang XR, Jia YJ, Tian X, Tian Q.
    Journal: Br J Radiol; 2016 Jun; 89(1062):20151022. PubMed ID: 27031376.
    Abstract:
    OBJECTIVE: To evaluate the clinical value of dual-energy spectral CT with adaptive statistical iterative reconstruction (ASiR) for reducing contrast medium dose in CT portal venography (CTPV). METHODS: This prospective study was institutional review board-approved, and written informed consent was obtained from all patients. 50 patients undergoing abdominal CT were randomized to 2 groups: Group A (n = 25), using spectral CT and 350 mgI kg(-1) contrast injection protocol; Group B (n = 25), using standard 120 kVp and 500 mgI kg(-1) contrast. Spectral CT images at 60 keV and standard 120-kVp images were both reconstructed with 50% ASiR. CT number and contrast-to-noise ratio (CNR) for intrahepatic and extrahepatic portal veins were measured. The maximum intensity projection (MIP) and volume-rendering (VR) images were used for subjective evaluation. These two kinds of results were statistically analyzed. RESULTS: CNR values for the intrahepatic portal vein of the 60-keV spectral images (4.2 ± 1.1) were higher than those of 120-kVp images (3.0 ± 2.1) (p = 0.03) and were the same for the extrahepatic portal vein (5.9 ± 1.4 vs 5.9 ± 1.6, p = 0.90). The portal vein and left and right branches in the 60-keV spectral images had higher CT number and lower standard deviation than the 120-kVp images (p < 0.05). Radiation dose (dose-length product and effective dose) and subjective image quality were similar for the two groups, while the spectral CT group required 25% less iodine dose (23.1 ± 3.2 g vs 30.5 ± 5.0 g). CONCLUSION: The 60-keV spectral CT images with ASiR allow 25% reduction in the iodine dose while providing better or equal image quality as the standard 120-kVp images in portal venography with comparable radiation dose. ADVANCES IN KNOWLEDGE: Compared with conventional 120-kVp CT, the use of 60-keV spectral CT images provides 25% contrast dose reduction with similar image quality in CTPV. Compared with conventional 120-kVp CT, the use of 60-keV spectral CT images with ASiR algorithm improves CNR values for the intrahepatic portal vein.
    [Abstract] [Full Text] [Related] [New Search]