These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Non-microbial sources of microbial volatile organic compounds. Author: Choi H, Schmidbauer N, Bornehag CG. Journal: Environ Res; 2016 Jul; 148():127-136. PubMed ID: 27043176. Abstract: BACKGROUND: The question regarding the true sources of the purported microbial volatile organic compounds (MVOCs) remains unanswered. OBJECTIVE: To identify microbial, as well as non-microbial sources of 28 compounds, which are commonly accepted as microbial VOCs (i.e. primary outcome of interest is Σ 28 VOCs). METHODS: In a cross-sectional investigation of 390 homes, six building inspectors assessed water/mold damage, took air and dust samples, and measured environmental conditions (i.e., absolute humidity (AH, g/m(3)), temperature (°C), ventilation rate (ACH)). The air sample was analyzed for volatile organic compounds (μg/m(3)) and; dust samples were analyzed for total viable fungal concentration (CFU/g) and six phthalates (mg/g dust). Four benchmark variables of the underlying sources were defined as highest quartile categories of: 1) the total concentration of 17 propylene glycol and propylene glycol ethers (Σ17 PGEs) in the air sample; 2) 2,2,4-trimethyl-1,3-pentanediol monoisobutyrate (TMPD-MIB) in the air sample; 3) semi-quantitative mold index; and 4) total fungal load (CFU/g). RESULTS: Within severely damp homes, co-occurrence of the highest quartile concentration of either Σ17 PGEs or TMPD-MIB were respectively associated with a significantly higher median concentration of Σ 28 VOCs (8.05 and 13.38μg/m(3), respectively) compared to the reference homes (4.30 and 4.86μg/m(3), respectively, both Ps ≤0.002). Furthermore, the homes within the highest quartile range for Σ fungal load as well as AH were associated with a significantly increased median Σ 28 VOCs compared to the reference group (8.74 vs. 4.32μg/m(3), P=0.001). Within the final model of multiple indoor sources on Σ 28 VOCs, one natural log-unit increase in summed concentration of Σ17 PGEs, plus TMPD-MIB (Σ 17 PGEs + TMPD-MIB) was associated with 1.8-times (95% CI, 1.3-2.5), greater likelihood of having a highest quartile of Σ 28 VOCs, after adjusting for absolute humidity, history of repainting at least one room, ventilation rate, and mold index (P-value =0.001). Homes deemed severely mold damaged (i.e., mold index =1) were associated with 1.7-times (95% CI, 0.8-3.6), greater likelihood of having a highest quartile of Σ 28 VOCs, even though such likelihood was not significant (P-value =0.164). In addition, absolute humidity appeared to positively interact with mold index to significantly elevate the prevalence of the highest quartile category of Σ 28 VOCs. CONCLUSION: The indoor concentration of Σ 28 VOCs, which are widely accepted as MVOCs, are significantly associated with the markers of synthetic (i.e. Σ17 PGEs and TMPD-MIB), and to less extent, microbial (i.e., mold index) sources.[Abstract] [Full Text] [Related] [New Search]