These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Biomechanical Comparison of Bicortical, Unicortical, and Unicortical Far-Cortex-Abutting Screw Fixations in Plated Comminuted Midshaft Clavicle Fractures.
    Author: Croley JS, Morris RP, Amin A, Lindsey RW, Gugala Z.
    Journal: J Hand Surg Am; 2016 Jun; 41(6):703-11. PubMed ID: 27113909.
    Abstract:
    PURPOSE: The objective of this study was to assess the biomechanical properties of bicortical locking screws, unicortical locking screws, and unicortical far-cortex-abutting locking screw fixation in a cadaver model of comminuted midshaft clavicle fractures stabilized with a locking plate placed on the superior surface of the clavicle. METHODS: Nine pairs of adult fresh-frozen cadaver clavicles were allocated into 3 groups for either bicortical, unicortical, or unicortical far-cortex-abutting locking plate fixation. After a 1-cm osteotomy to simulate a comminuted fracture and instrumentation with an 8-hole locking plate placed on the superior surface of the clavicle, the specimens were mounted in a custom dual-gimbal fixture in a materials-testing system and tested in axial compression, torsional, and torsional load to failure. RESULTS: Axial stiffness and axial osteotomy site stiffness did not demonstrate differences between constructs. In cyclical torsion, both the bicortical and the unicortical far-cortex-abutting constructs were significantly stiffer than the unicortical construct. For torsional failure stiffness, both the bicortical and the unicortical far-cortex-abutting constructs were significantly stiffer than the unicortical construct. There was no difference between bicortical and unicortical far-cortex-abutting for torsional failure stiffness. The bicortical construct exhibited significantly higher peak failure torque compared with the unicortical construct. CONCLUSIONS: Unicortical far-cortex-abutting locking screw fixation provides comparable mechanical properties under axial and torsional loads to bicortical fixation, without penetrating the far cortex. CLINICAL RELEVANCE: Unicortical far-cortex-abutting locking screw fixation obviates far cortex penetration, and thereby protects nearby anatomical structures, may ease symptomatic implant removal, alleviates refracture risk, and eases conversion to bicortical fixation in the case of revision surgery.
    [Abstract] [Full Text] [Related] [New Search]