These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Macroindentation hardness measurement-Modernization and applications.
    Author: Patel S, Sun CC.
    Journal: Int J Pharm; 2016 Jun 15; 506(1-2):262-7. PubMed ID: 27130365.
    Abstract:
    In this study, we first developed a modernized indentation technique for measuring tablet hardness. This technique is featured by rapid digital image capture, using a calibrated light microscope, and precise area-determination. We then systematically studied effects of key experimental parameters, including indentation force, speed, and holding time, on measured hardness of a very soft material, hydroxypropyl cellulose, and a very hard material, dibasic calcium phosphate, to cover a wide range of material properties. Based on the results, a holding period of 3min at the peak indentation load is recommended to minimize the effect of testing speed on H. Using this method, we show that an exponential decay function well describes the relationship between tablet hardness and porosity for seven commonly used pharmaceutical powders investigated in this work. We propose that H and H at zero porosity may be used to quantify the tablet deformability and powder plasticity, respectively.
    [Abstract] [Full Text] [Related] [New Search]