These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Liver Fibrosis Evaluation Using Real-time Shear Wave Elastography in Hepatitis C-Monoinfected and Human Immunodeficiency Virus/Hepatitis C-Coinfected Patients.
    Author: Verlinden W, Bourgeois S, Gigase P, Thienpont C, Vonghia L, Vanwolleghem T, Michielsen P, Francque S.
    Journal: J Ultrasound Med; 2016 Jun; 35(6):1299-308. PubMed ID: 27151906.
    Abstract:
    OBJECTIVES: A few studies have evaluated real-time shear wave elastography (SWE) for assessing liver fibrosis by measuring liver stiffness in patients with chronic hepatitis C virus (HCV) infection, but they excluded human immunodeficiency virus/HCV-coinfected patients. We investigated the diagnostic performance of liver stiffness measured by SWE as a noninvasive predictor of liver fibrosis in HCV using liver biopsy as a reference standard, including monoinfected and coinfected patients. METHODS: We measured liver stiffness in patients with HCV undergoing liver biopsy (METAVIR fibrosis staging). RESULTS: Eighty patients (53 monoinfected and 27 coinfected) were included. There was a significant correlation between liver stiffness and fibrosis stage (ρ = 0.685; P < .001). Areas under the receiver operating characteristic curve were 0.841, 0.879, and 0.975 when comparing fibrosis stages F0-F1 versus F2-F4, F0-F2 versus F3-F4, and F0-F3 versus F4, respectively. Suggested cutoff values were 8.5 kPa for F2, 10.4 kPa for F3, and 11.3 kPa for F4, with sensitivity and specificity of 81% and 84%, 81% and 95%, and 100% and 90%. There was no significant difference between the liver stiffness of monoinfected and coinfected patients (P = .453). When combining SWE with the fibrosis-4 score, accuracy increased from 82% to 88% and from 88% to 96%, with incongruent results of 26% and 29%, for F0-F1 versus F2-F4 and F0-F2 versus F3-F4. CONCLUSIONS: Shear wave elastography of the liver is an effective noninvasive predictor of liver fibrosis in patients with HCV. There was no significant difference between monoinfected and coinfected patients; hence, the same cutoff values can be used for both groups. Combination of SWE with the fibrosis-4 score leads to higher accuracy, although at the expense of inconclusive results in some patients.
    [Abstract] [Full Text] [Related] [New Search]