Title: Myocardial Structural and Functional Response After Long-Term Mechanical Unloading With Continuous Flow Left Ventricular Assist Device: Axial Versus Centrifugal Flow. Author: Al-Sarie M, Rauf A, Kfoury AG, Catino A, Wever-Pinzon J, Bonios M, Horne BD, Diakos NA, Wever-Pinzon O, McKellar SH, Kelkhoff A, McCreath L, Fang J, Stehlik J, Selzman CH, Drakos SG. Journal: JACC Heart Fail; 2016 Jul; 4(7):570-576. PubMed ID: 27179831. Abstract: OBJECTIVES: The aim of this study was to assess the impact of continuous-flow left ventricular assist device (LVAD) type-axial flow (AX) versus centrifugal flow (CR)-on myocardial structural and functional response following mechanical unloading. BACKGROUND: The use of continuous-flow LVADs is increasing steadily as a therapeutic option for patients with end-stage heart failure who are not responsive to medical therapy. Whether the type of mechanical unloading influences the myocardial response is yet to be determined. METHODS: A total of 133 consecutive patients with end-stage heart failure implanted with continuous-flow LVADs (AX, n = 107 [HeartMate II Thoratec Corporation, Pleasanton, California]; CR, n = 26 [HeartWare, HeartWare International, Framingham, Massachusetts]) were prospectively studied. Echocardiograms were obtained pre-LVAD implantation and then serially at 1, 2, 3, 4, 6, 9, and 12 months post-implantation. RESULTS: The 2 pump types led to similar degrees of mechanical unloading as assessed by invasive hemodynamic status and frequency of aortic valve opening. Myocardial structural and functional parameters showed significant improvement post-LVAD in both AX and CR groups. Left ventricular ejection fraction increased significantly from a mean of 18% to 28% and 26% post-LVAD in the AX and CR groups, respectively. Left ventricular end-systolic volume index and left ventricular end-diastolic volume index decreased significantly as early as 30 days post-implantation in the 2 groups. The degree of myocardial structural or functional response between patients in the AX or CR groups appeared to be comparable. CONCLUSIONS: Long-term mechanical unloading induced by AX and CR LVADs, while operating within their routine clinical range, seems to exert comparable effects on myocardial structural and functional parameters.[Abstract] [Full Text] [Related] [New Search]