These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Sequential fetal serum β2-microglobulin to predict postnatal renal function in bilateral or low urinary tract obstruction.
    Author: Spaggiari E, Faure G, Dreux S, Czerkiewicz I, Stirnemann JJ, Guimiot F, Heidet L, Favre R, Salomon LJ, Oury JF, Ville Y, Muller F.
    Journal: Ultrasound Obstet Gynecol; 2017 May; 49(5):617-622. PubMed ID: 27197901.
    Abstract:
    OBJECTIVE: Fetal serum β2-microglobulin has been shown to predict postnatal renal outcome in cases of fetal obstructive uropathy. We assessed the value of serial measurements of fetal serum β2-microglobulin in the prediction of postnatal renal outcome. METHODS: We retrospectively studied renal outcome in 42 fetuses with bilateral or low urinary tract obstruction that had fetal blood sampling on at least two occasions to assay serum levels of β2-microglobulin. Amniotic fluid volume at the time of each sampling was recorded. We classified renal outcome as either favorable (when postnatal renal function was normal) or adverse (when postnatal chronic renal failure occurred or when renal dysplasia at autopsy was noted). A β2-microglobulin cut-off of 5 mg/L and amniotic fluid index of 5 cm were used to predict postnatal renal outcome. RESULTS: Renal outcome was adverse in 28 cases and favorable in 14. In 12 (28.6%) cases, fetal serum β2-microglobulin concentration differed between the first and last measurement. Prediction of postnatal renal outcome was correct in 11 of these cases based on the last β2-microglobulin measurement. The sensitivity of β2-microglobulin in predicting renal outcome was significantly higher (P = 0.005) when using the last rather than the first measurement (96.4% vs 64.3%), with similar specificity for both measurements (85.7% vs 78.6%, non-significant). The sensitivity of amniotic fluid volume was also significantly higher (P = 0.005) when using the last rather than the first measurement (75.0% vs 35.7%), with similar specificity for both measurements (64.3% vs 71.4%, non-significant). CONCLUSION: Sequential measurement of serum β2-microglobulin, performed for adverse ultrasound findings, such as renal parenchymal abnormality or decreasing amniotic fluid volume, predicts postnatal renal outcome more accurately than does a single assay. This may be due to possible worsening of renal injury with increasing duration of urinary tract obstruction. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd.
    [Abstract] [Full Text] [Related] [New Search]