These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Clinical utility of a Bayesian dosing program for phenytoin.
    Author: Privitera MD, Homan RW, Ludden TM, Peck CC, Vasko MR.
    Journal: Ther Drug Monit; 1989; 11(3):285-94. PubMed ID: 2728087.
    Abstract:
    We performed two studies to assess the clinical utility of a Bayesian regression analysis computer program for phenytoin (PHT). In a randomized prospective study of 40 epileptic patients, the dosing program was significantly more accurate (p = 0.002) and less biased (p = 0.02) than a group of physicians at hitting a target PHT serum-concentration. Initial serum PHT concentrations that were not steady state were associated with the largest dosing errors by physicians but did not affect the accuracy of the dosing program. In a second study, we used the dosing program to predict 91 serum concentrations in 31 patients with PHT toxicity after the drug was stopped (initial concentration 26-69 micrograms/ml). The program predicted serum concentrations with a mean error of 3.49 +/- 0.29 micrograms/ml without significant tendency to over- or underpredict. We conclude that this dosing program may aid clinicians by improving dosing accuracy and predicting serum concentrations in patients with PHT toxicity.
    [Abstract] [Full Text] [Related] [New Search]