These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: MRI-Based Liver Iron Content Determination at 3T in Regularly Transfused Patients by Signal Intensity Ratio Using an Alternative Analysis Approach Based on R2* Theory. Author: Wunderlich AP, Cario H, Bommer M, Beer M, Schmidt SA, Juchems MS. Journal: Rofo; 2016 Sep; 188(9):846-52. PubMed ID: 27299667. Abstract: OBJECTIVES: To evaluate the feasibility of addressing liver iron content (LIC) in regularly transfused patients by MR imaging at 3 T based on the signal intensity ratio (SIR). An innovative data analysis approach was developed for this purpose. METHODS: 47 consecutive examinations of regularly transfused patients were included. In all cases, we expected high LIC levels. Patients were scanned with MRI at 3 T with multi-echo gradient echo sequences (GRE) at four different flip angles between 20° and 90° with echo times (TE) ranging from 0.9 to 9.8 ms. Spin-echo protocols were acquired to determine the LIC with a reference MRI method working at 1.5 T. 3 T GRE data were analyzed using the liver-to-muscle SIR. Since the method known for 1.5 T was not expected to be applicable for analyzing 3 T data, theoretic dependence of the SIR on the LIC was derived from the equation describing R2* signal decay. Obtained SIR values were correlated to reference LIC to get a relation for calculating LIC from SIR quantities. LIC values and their uncertainties were determined from GRE data and correlated to LIC reference values. For two LIC thresholds, the diagnostic accuracy was determined. RESULTS: LIC was reliably determined from SIR in our patient cohort even for large LIC values. Median of LIC uncertainties was 10 %, and the diagnostic accuracy was 0.92 and 0.91, respectively. CONCLUSION: Determination of even high LIC, resulting in small SIR values, is feasible at 3 T using appropriate SIR analysis. KEY POINTS: • Determination of Liver Iron Concentration (LIC) based on GRE MRI at 3T is feasible even for high LIC levels using Signal Intensiy Ratios. • Relative uncertainty of LIC determined with 3T GRE MRI was below 13 % in most cases. • The patient-management relevant threshold (LIC = 80 µmol/g (4.5 mg/g)) yielded an accuracy of .92 in our cohort. • The proposed method is quick and simple, both in terms of data acquisition and analysis. Citation Format: • Wunderlich AP, Cario H, Bommer M et al. MRI-Based Liver Iron Content Determination at 3T in Regularly Transfused Patients by Signal Intensity Ratio Using an Alternative Analysis Approach Based on R2* Theory. Fortschr Röntgenstr 2016; 188: 846 - 852.[Abstract] [Full Text] [Related] [New Search]