These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Simultaneous Determination of Hydrochlorothiazide and Losartan Potassium in Osmotic Pump Tablets by Microemulsion Liquid Chromatography. Author: Li L, Lai C, Xuan X, Gao C, Li N. Journal: J Chromatogr Sci; 2016 Sep; 54(8):1415-20. PubMed ID: 27334292. Abstract: A rapid and efficient oil-in-water microemulsion liquid chromatographic (MELC) method has been optimized and validated for the determination of hydrochlorothiazide (HCT) and losartan potassium (LOP) in osmotic pump tablets. Samples were injected into a C18 (150 mm × 4.6 mm ID, 5 µm particle size) analytical column, which was maintained at 30°C. The most effective MELC system had a mobile phase consisting of 95% (v/v) of 3.0% (w/w) SDS, 6.0% (w/w) n-butanol, 0.8% (w/w) n-octane, 90.2% (w/w) water and 5% (v/v) acetonitrile (pH 5). The flow rate was 1.0 mL min(-1) and UV detection was performed at 265 nm. Linearity ranged from 2.5 to 12.5 µg mL(-1) for HCT and 10.0-60.0 µg mL(-1) for LOP (r > 0.999 for both drugs). The proposed method was rapid, precise (RSDs < 1.4%) and accurate (98.9% recovery for HCT and 101% recovery for LOP). It is applicable to simultaneous determination of HCT and LOP in osmotic pump tablets.[Abstract] [Full Text] [Related] [New Search]