Title: Active middle ear implant coupled bilaterally to the round window despite bilateral implanted stapes prostheses. Author: Coordes A, Jahreiss L, Schönfeld U, Lenarz M. Journal: Laryngoscope; 2017 Feb; 127(2):500-503. PubMed ID: 27346704. Abstract: After stapes surgery, patients with mixed or moderate hearing loss have limited possibilities for hearing improvement. We are reporting on a patient who underwent stapedotomy bilaterally 20 years ago and had sensorineural and mixed hearing loss. Recurrent otitis externa prevented the use of hearing aids. This patient was treated bilaterally with the Vibrant Soundbridge (Med-El, Innsbruck, Austria) successively. The Schuknecht piston stapes prostheses remained in situ. The Floating Mass Transducer (FMT; Med-El) was coupled to the round window (RW) and provided good acoustic reinforcement bilaterally. In conclusion, for patients with otosclerosis and stapes surgery, the FMT-RW coupling (Bess AG, Berlin, DE) is a safe procedure with good acoustic amplification. Laryngoscope, 2016 127:500-503, 2017.[Abstract] [Full Text] [Related] [New Search]