  • Title: Accurate in vivo dielectric properties of liver from 500 MHz to 40 GHz and their correlation to ex vivo measurements.
    Author: Farrugia L, Wismayer PS, Mangion LZ, Sammut CV.
    Journal: Electromagn Biol Med; 2016; 35(4):365-73. PubMed ID: 27432640.
    Abstract:
    In this article, we report on the characterization of the dielectric properties of in vivo rat liver at 36.4°C from 500 MHz up to 40 GHz with less than 5% uncertainty. The measured data were fitted to a Cole-Cole model and dielectric parameters are presented together with their respective 95% confidence interval. The root mean square error is 0.42. Moreover, ex vivo measurements were conducted in situ at 1, 2, 4 and 6 min after animal death and are compared to in vivo measurements. The results show that immediate changes in [Formula: see text]and [Formula: see text] are within experimental uncertainty, and therefore changes between in vivo and published ex vivo dielectric properties can be attributed to tissue hydration.