These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Improved border sharpness of post-infarct scar by a novel self-navigated free-breathing high-resolution 3D whole-heart inversion recovery magnetic resonance approach.
    Author: Rutz T, Piccini D, Coppo S, Chaptinel J, Ginami G, Vincenti G, Stuber M, Schwitter J.
    Journal: Int J Cardiovasc Imaging; 2016 Dec; 32(12):1735-1744. PubMed ID: 27549804.
    Abstract:
    The border zone of post-infarction myocardial scar as identified by late gadolinium enhancement (LGE) has been identified as a substrate for arrhythmias and consequently, high-resolution 3D scar information is potentially useful for planning of electrophysiological interventions. This study evaluates the performance of a novel high-resolution 3D self-navigated free-breathing inversion recovery magnetic resonance pulse sequence (3D-SN-LGE) vs. conventional 2D breath-hold LGE (2D-LGE) with regard to sharpness of borders (SBorder) of post-infarction scar. Patients with post-infarction scar underwent two magnetic resonance examinations for conventional 2D-LGE and high-resolution 3D-SN-LGE acquisitions (both 15 min after 0.2 mmol/kg Gadobutrol IV) at 1.5T. In the prototype 3D-SN-LGE sequence, each ECG-triggered radial steady-state-free-precession read-out segment is preceded by a non-slice-selective inversion pulse. Scar volume and SBorder were assessed on 2D-LGE and matching reconstructed high-resolution 3D-SN-LGE short-axis slices. In 16 patients (four females, 58 ± 10y) all scars visualized by 2D-LGE could be identified on 3D-SN-LGE (time between 2D-LGE and 3D-SN-LGE 48 ± 53 days). A good agreement of scar volume by 3D-SN-LGE vs. 2D-LGE was found (Bland-Altman: -3.7 ± 3.4 ml, correlation: r = 0.987, p < 0.001) with a small difference in scar volume (20.5 (15.8, 35.2) ml vs. 24.5 (20.0, 41.9)) ml, respectively, p = 0.002] and a good intra- and interobserver variability (1.1 ± 4.1 and -1.1 ± 11.9 ml, respectively). SBorder of border "scar to non-infarcted myocardium" was superior on 3D-SN-LGE vs. 2D-LGE: 0.180 ± 0.044 vs. 0.083 ± 0.038, p < 0.001. Detection and quantification of myocardial scar by 3D-SN-LGE is feasible and accurate in comparison to 2D-LGE. The high spatial resolution of the 3D sequence improves delineation of scar borders.
    [Abstract] [Full Text] [Related] [New Search]