These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Prospective Evaluation of Passive Expansion of Partially Dilated Transjugular Intrahepatic Portosystemic Shunt Stent Grafts-A Three-Dimensional Sonography Study.
    Author: Pieper CC, Jansen C, Meyer C, Nadal J, Lehmann J, Schild HH, Trebicka J, Thomas D.
    Journal: J Vasc Interv Radiol; 2017 Jan; 28(1):117-125. PubMed ID: 27553918.
    Abstract:
    PURPOSE: To prospectively investigate early expansion kinetics of underdilated self-expanding stent grafts used for transjugular intrahepatic portosystemic shunt (TIPS) creation. MATERIALS AND METHODS: Twenty patients (7 female; mean age 66 y; range, 31-80 y) with liver cirrhosis undergoing TIPS creation for variceal bleeding (n = 5), refractory ascites (n = 14), or both (n = 1) with underdilation of 10-mm stent grafts received two-dimensional (2-D) and three-dimensional (3-D) ultrasound (US) examinations immediately after TIPS creation and 1 and 6 weeks later. Orthogonal views of the TIPS within the parenchymal tract were reconstructed from 3-D volume data sets acquired in longitudinal orientation of the stent. 2-D images and reconstructed 3-D images were used for blinded diameter measurements. Measurement technique was validated with intrainterventional plain radiographs with a sizing catheter as the gold standard. Diameter changes over time and interrelations with patient characteristics (null hypothesis: no expansion, no interrelation) were analyzed using a general linear model for repeated measures. RESULTS: After dilation to 8-mm diameter, 2-D and 3-D measurements showed stent recoil (mean diameter 7.7 mm ± 0.21 and 7.6 mm ± 0.17, respectively). Diameter increased significantly from initial measurements to measurements at 1 and 6 weeks (2-D, 8.8 mm ± 0.24 and 9.4 mm ± 0.15, both P < .001; 3-D, 8.7 mm ± 0.27 and 9.4 mm ± 0.11, both P < .001). Validation measurements showed no significant differences between 2-D or 3-D US and gold standard. There were no statistically significant associations between stent expansion and clinical parameters (sex, P = .78; age, P = .82; etiology/grade of cirrhosis, P = .99; indication for TIPS, P = .78, liver stiffness, P = .70). CONCLUSIONS: Underdilated self-expanding stent grafts used for TIPS creation significantly expand within first 6 weeks after intervention. These changes can be noninvasively monitored using 3-D US.
    [Abstract] [Full Text] [Related] [New Search]