These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Comparisons of Serum Infliximab and Antibodies-to-Infliximab Tests Used in Inflammatory Bowel Disease Clinical Trials of Remicade®.
    Author: Marini JC, Sendecki J, Cornillie F, Popp JW, Black S, Blank M, Gils A, Van Stappen T, Hamann D, Rispens T, Thérien L, Chun K, Shankar G.
    Journal: AAPS J; 2017 Jan; 19(1):161-171. PubMed ID: 27600137.
    Abstract:
    Monitoring infliximab (IFX) concentrations and antibodies-to-IFX (ATI) titers during inflammatory bowel disease treatment may allow more informed decisions in assessing exposure/response and determining appropriate dosing. To aid in interpreting results from different commercial tests in the context of Janssen's published Remicade® results, the reliability of Janssen's IFX and ATI assays was compared with commercial assays from KU Leuven, Sanquin, Dynacare, and LabCorp. Test results were independently reported to Janssen. All assays were tested for specificity, selectivity, and precision. ATI assays were evaluated for sensitivity, drug interference, and potential interference of tumor necrosis factor-alpha (TNF-α). IFX assays were specific, accurate, and reproducible. Intra-class correlation of Janssen IFX assay results with those from KU Leuven, Sanquin, Dynacare, and LabCorp were 0.960, 0.895, 0.931, and 0.971, respectively. ATI titers >10 interfered with IFX assessment in all IFX assays, whereas TNF-α (≤50 ng/mL) did not interfere with IFX detection in any assay. ATI assays specifically and reproducibly detected ATI. Janssen, Sanquin, and LabCorp ATI methods were more resistant to IFX interference than Dynacare and KU Leuven, which were affected by IFX concentrations at ≥2 μg/mL. TNF-α (<5 ng/mL) did not interfere with ATI detection. Strong agreement was observed between Janssen's IFX and ATI assays and the diagnostic service provider assays. Our study results indicate that all four commercially available assays are suitable for therapeutic drug monitoring of IFX. The substantial agreement reported here between the comparator assays and the Janssen drug-tolerant assay provides support to clinicians in their use of these commercial assays, and for understanding their patients' IFX and ATI results relative to published data from clinical studies of Remicade.
    [Abstract] [Full Text] [Related] [New Search]