These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Effects of Changes in BI-RADS Density Assessment Guidelines (Fourth Versus Fifth Edition) on Breast Density Assessment: Intra- and Interreader Agreements and Density Distribution.
    Author: Irshad A, Leddy R, Ackerman S, Cluver A, Pavic D, Abid A, Lewis MC.
    Journal: AJR Am J Roentgenol; 2016 Dec; 207(6):1366-1371. PubMed ID: 27656766.
    Abstract:
    OBJECTIVE: The objective of our study was to determine intra- and interreader agreements for density assessment using the fifth edition of the BI-RADS guidelines and to compare with those for density assessment using the fourth edition of the BI-RADS guidelines. MATERIALS AND METHODS: Five radiologists assessed breast density four times in 104 mammographic examinations: twice using the fourth edition of the BI-RADS guidelines and twice using the fifth edition. The intra- and interreader agreements for density assessment based on each guideline were determined and compared. The density distribution pattern under each of the four BI-RADS density categories using each guideline was also noted and compared. RESULTS: The intrareader agreement for density assessment using the fifth-edition criteria was lower than that using the fourth-edition criteria (p = 0.0179). The overall intrareader agreement (weighted kappa) using the old criteria was 0.84 (95% CI, 0.80-0.87), and the individual intrareader agreement values in five readers ranged from 0.78 (95% CI, 0.69-0.88) to 0.92 (95% CI, 0.87-0.97). The overall intrareader agreement using the new BI-RADS criteria was 0.77 (95% CI, 0.73-0.81), and the individual intrareader agreement values in five readers ranged from 0.74 (95% CI, 0.64-0.84) to 0.99 (95% CI, 0.98-1.00). The interreader agreement values obtained using the fifth-edition criteria were also lower than those obtained using the fourth-edition criteria (p = 0.006). The overall interreader agreement using the old BI-RADS criteria was 0.65 (95% CI, 0.61-0.69), whereas the overall interreader agreement using the new BI-RADS criteria was 0.57 (95% CI, 0.53-0.61). Overall a higher number of dense assessments were given when the fifth-edition guidelines were used (p < 0.0001). CONCLUSION: Compared with the intra- and interreader agreements obtained using the fourth edition of the BI-RADS guidelines, the intra- and interreader agreements were lower using the fifth-edition guidelines. An increased number of dense assessments were given when the fifth-edition guidelines were used.
    [Abstract] [Full Text] [Related] [New Search]