These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Does an additional antirotation U-Blade (RC) lag screw improve treatment of AO/OTA 31 A1-3 fractures with gamma 3 nail? Author: Lang NW, Arthold C, Joestl J, Gormasz A, Boesmueller S, Hajdu S, Sarahrudi K. Journal: Injury; 2016 Dec; 47(12):2733-2738. PubMed ID: 27832831. Abstract: INTRODUCTION: Poor bone quality and unstable fractures increase the cut-out rate in implants with gliding lag screws. The U-Blade (RC) lag screw for the Gamma3® nail was introduced to provide monoaxial rotational stability of the femoral head and neck fragment. The purpose of this study was to evaluate whether the use of the U-Blade (RC) lag screw is associated with reduced cut-out in patients with OTA/AO 31A1-3 fractures. MATERIAL & METHODS: Between 2009 and 2014, 751 patients with OTA/AO 31A1-3 fractures were treated with a Gamma3® nail at our institution. Out of this sample 199 patients were treated with U-blade (RC) lag screws. A total of 135 patients (117 female, 18 male) with standard lag screw (treatment group A) were matched equally regarding age (±4 years) sex, fracture type and location to 135 patients with U-blade (RC) lag screw (treatment group B). Within a mean follow up of 9.2 months (range 6-18 months) we assessed the cut-out rate, the calTAD, lag screw migration, the Parker's mobility score and the Parker's ratio at postoperatively, six and 12 months following surgery. Furthermore we recorded all complications, ASA-Score, hospital stay and duration of surgery retrospectively. RESULTS: The most common fracture among group B with a cut-out of the lag screw were AO/OTA 2.3 and 3.2 fractures whereas in group A cut-out was most commonly seen in AO/OTA 2.1, 2.2 and 2.3 fractures, there was no significant reduction of the cut-out rate in group B 2.2% (n=3) compared to group A 3.7% (n=5). The duration of surgery was significantly shorter in group A (p<0.05). There was no significant difference in lag screw placement, the Parker's ratio and mobilization. CONCLUSION: In our study the U-Blade (RC) lag screw did not reduce the cut-out in treatment of OTA/AO 31A1-3 fractures at all. Considering the longer duration of surgery and the higher costs of the U-Blade (RC) lag screw, our results do not justify its use. However, further prospective randomized studies will be necessary.[Abstract] [Full Text] [Related] [New Search]