These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Reliability and Concurrent Validity of the Narrow Path Walking Test in Persons With Multiple Sclerosis. Author: Rosenblum U, Melzer I. Journal: J Neurol Phys Ther; 2017 Jan; 41(1):43-51. PubMed ID: 27977520. Abstract: BACKGROUND AND PURPOSE: About 90% of people with multiple sclerosis (PwMS) have gait instability and 50% fall. Reliable and clinically feasible methods of gait instability assessment are needed. The study investigated the reliability and validity of the Narrow Path Walking Test (NPWT) under single-task (ST) and dual-task (DT) conditions for PwMS. METHODS: Thirty PwMS performed the NPWT on 2 different occasions, a week apart. Number of Steps, Trial Time, Trial Velocity, Step Length, Number of Step Errors, Number of Cognitive Task Errors, and Number of Balance Losses were measured. Intraclass correlation coefficients (ICC2,1) were calculated from the average values of NPWT parameters. Absolute reliability was quantified from standard error of measurement (SEM) and smallest real difference (SRD). Concurrent validity of NPWT with Functional Reach Test, Four Square Step Test (FSST), 12-item Multiple Sclerosis Walking Scale (MSWS-12), and 2 Minute Walking Test (2MWT) was determined using partial correlations. RESULTS: Intraclass correlation coefficients (ICCs) for most NPWT parameters during ST and DT ranged from 0.46-0.94 and 0.55-0.95, respectively. The highest relative reliability was found for Number of Step Errors (ICC = 0.94 and 0.93, for ST and DT, respectively) and Trial Velocity (ICC = 0.83 and 0.86, for ST and DT, respectively). Absolute reliability was high for Number of Step Errors in ST (SEM % = 19.53%) and DT (SEM % = 18.14%) and low for Trial Velocity in ST (SEM % = 6.88%) and DT (SEM % = 7.29%). Significant correlations for Number of Step Errors and Trial Velocity were found with FSST, MSWS-12, and 2MWT. DISCUSSION AND CONCLUSIONS: In persons with PwMS performing the NPWT, Number of Step Errors and Trial Velocity were highly reliable parameters. Based on correlations with other measures of gait instability, Number of Step Errors was the most valid parameter of dynamic balance under the conditions of our test.Video Abstract available for more insights from the authors (see Supplemental Digital Content 1, available at: http://links.lww.com/JNPT/A159).[Abstract] [Full Text] [Related] [New Search]