These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: On-line prediction of sodium content in vacuum packed dry-cured ham slices by non-invasive near infrared spectroscopy.
    Author: Campos MI, Mussons ML, Antolin G, Debán L, Pardo R.
    Journal: Meat Sci; 2017 Apr; 126():29-35. PubMed ID: 28002759.
    Abstract:
    In the present study, non-invasive near infrared spectroscopy (NIRS) was evaluated as a potential on-line analytical technique to predict the sodium content in dry-cured ham slices. Samples of 310 packages were scanned by applying a remote fibre-optic probe to the surface of the slices, at different temperatures, with no previous manipulation. The sodium content of the meat samples was determined by a reference method based on Inductively Coupled Plasma Atomic Emission Spectrophotometry (ICP-AES) after chemical digestion. Partial least squares (PLS) regression was used as a chemometrics method to perform the calibrations. The models yielded acceptable results with cross validation correlation coefficients (R2CV) determined 86.2-90.2%. The prediction capacity reached in the external validation was 3.63, with a standard prediction error of 0.12% Na. These results show that NIR measurements could be implemented on the packaging line of dry-cured ham slices to provide accurate and relevant information about the sodium content of each packaged products.
    [Abstract] [Full Text] [Related] [New Search]