These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Chemiluminescent assay of co-factors.
    Author: Tsuji A, Maeda M, Arakawa H.
    Journal: J Biolumin Chemilumin; 1989 Jul; 4(1):454-62. PubMed ID: 2801232.
    Abstract:
    Bioluminescent methods are widely used for the assay of the co-factors, NADH and ATP. Although the bioluminescent method is highly sensitive, the enzymes used are unstable and expensive. Therefore a chemiluminescent method would be valuable in clinical routine assay. We have developed a chemiluminescent method for the assay of NADH using the 1-methoxy-5-methylphenazinium methyl sulphate (1-MPMS)/isoluminol(IL)/microperoxidase(m-POD) system. In order to increase the sensitivity of this method, enzymatic cycling system was coupled to the chemiluminescent assay of NADH. Alcohol dehydrogenase and malate dehydrogenase were used as the cycling enzyme. The standard curve was obtained in the range from 3 X 10(-14) to 5 X 10(-12) mol/assay. The detection limit of NADH was 30 fmol/assay which was comparable to that of the bioluminescent method using bacterial luciferase. Two chemiluminescent methods for the assay of ATP have been developed. Method 1 is the system using hexokinase/G6PDH and 1-PMS/IL/m-POD, and method 2 is the system based on the enzymatic cycling reaction of ATP using hexokinase/pyruvate kinase. Method 2 is 1000/fold more sensitive than the method 1. The detection limit of ATP was 10 fmol/assay.
    [Abstract] [Full Text] [Related] [New Search]