These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: The evolution of radiation dose over time: Measurement of a patient cohort undergoing whole-body examinations on three computer tomography generations. Author: Marcus RP, Koerner E, Aydin RC, Zinsser D, Finke T, Cyron CJ, Bamberg F, Nikolaou K, Notohamiprodjo M. Journal: Eur J Radiol; 2017 Jan; 86():63-69. PubMed ID: 28027768. Abstract: OBJECTIVES: To evaluate and compare the radiation dose and image quality of whole-body-CT (WBCT) performed on the 3rd-generation dual-source-CT (DSCT) with 2nd-generation DSCT and 64-slices-Single-Source-CT (SSCT) in a large patient cohort. MATERIAL AND METHODS: Using a monitoring and tracking software 1451, 747 and 1861 patients scanned with a one-spiral-thorax-abdomen-pelvis-CT-examination on a 3rd-, 2nd-generation DSCT and SSCT, respectively, were extracted from the PACS server. For the intra-individual analysis, 203 patients on the 3rd-generation DSCT were identified. Out of those 203 patients, 155 had the same examination on the 2nd-generation DSCT, 91 patients had the same examination on the SSCT and 43 patients had an examination on all three CT-generations. Automatic tube current modulation was active on all three CT-generations, whereas automatic tube voltage selection was only available on both DSCT-generations. Dose was recorded by the size-specific-dose-estimate-method (SSDE); signal-to-noise-ratio (SNR) and contrast-to-noise-ratio (CNR) were calculated placing a ROI on the ascending aorta/liver and the subcutaneous adipose tissue at comparable level. Image quality of axillary and mediastinal lymph nodes and adrenal glands was assessed by two experienced radiologists. RESULTS: Subjective image quality was excellent throughout all three CT-generations (p=0.38-0.98). Quantitative image quality in both DSCT generations was superior to SSCT (p<0.001). SNR and CNR in the liver parenchyma were superior in the 3rd-generation DSCT compared to the 2nd generation DSCT (p<0.001), whereas there was no difference in the aorta. In the inter-individual analysis, CTDIvol was lower by 26.9% and 44.3% in the 3rd-generation DSCT, when compared to the 2nd-generation DSCT and SSCT, respectively; SSDE was lower by 31.5% and 51% in the 3rd-generation DSCT, when compared to the 2nd-generation DSCT and SSCT, respectively. In the intra-individual comparison CTDIVol in the 3rd-generation DSCT was lower by 33% and 45%, when compared to the 2nd-gneration DSCT and the SSCT, respectively. Consequently, SSDE in the 3rd-generation DSCT was lower by 29% and by 43% when compared to the 2nd-generation DSCT and SSCT, respectively. CONCLUSION: State-of-the-art CT-equipment substantially reduce radiation dose without affecting image quality.[Abstract] [Full Text] [Related] [New Search]