These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Estimation of Central Venous Pressure Using the Ratio of Short to Long Diameter from Cross-Sectional Images of the Inferior Vena Cava. Author: Seo Y, Iida N, Yamamoto M, Machino-Ohtsuka T, Ishizu T, Aonuma K. Journal: J Am Soc Echocardiogr; 2017 May; 30(5):461-467. PubMed ID: 28065586. Abstract: BACKGROUND: Long-axis images of the inferior vena cava (IVC) have limitations as surrogates for IVC morphology in grading central venous pressure (CVP) by two-dimensional echocardiography (2DE), because of the various cross-sectional morphologies and the translational motion of the IVC induced by sniffing. On the basis of the relationship between venous pressure and compliance, it was hypothesized that the cross-sectional morphology of the IVC, which was obtained using three-dimensional echocardiography, might estimate CVP more accurately compared with standard grading by 2DE. METHODS: Sixty consecutive patients who underwent right-heart catheterization studies were prospectively enrolled. Echocardiography was performed <24 hours before catheterization. From three-dimensional data sets, a cross-section of the IVC was determined that was perpendicular to the long-axis reference of the IVC. Short diameter (SD), long diameter (LD), the ratio of SD to LD (S/L) as the sphericity index, and area were measured on this cross-sectional IVC image. RESULTS: CVP correlated moderately with SD (r = 0.69, P < .001), strongly with S/L (r = 0.75, P < .001), and modestly with area (r = 0.47, P < .001) but not with LD (r = 0.24, P = .17). The largest areas under the curve by receiver operating characteristic analyses to detect CVP ≥ 10 mm Hg were 0.98 (95% CI, 0.97-1.0; P < .001) for S/L, 0.83 for SD (95% CI, 0.74-0.94; P < .001), and 0.70 for area (95% CI, 0.56-0.84; P = .02). If a cutoff value of 0.69 for S/L was used, the sensitivity, specificity, and accuracy to detect CVP ≥ 10 mm Hg were 0.94, 0.95, and 0.95 and for CVP grading by 2DE were 0.59, 0.98, and 0.85, respectively. Estimations of CVP were more accurately reclassified using S/L rather than grading by 2DE (net reclassification improvement, 0.38; 95% CI, 0.31-0.44; P < .001). CONCLUSIONS: S/L of an IVC cross-section measured using three-dimensional echocardiography may be a reliable parameter to estimate CVP compared with standard grading by 2DE.[Abstract] [Full Text] [Related] [New Search]