These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Randomized Multicenter Trial Investigating Angiographic Outcomes of Hybrid Sirolimus-Eluting Stents With Biodegradable Polymer Compared With Everolimus-Eluting Stents With Durable Polymer in Chronic Total Occlusions: The PRISON IV Trial. Author: Teeuwen K, van der Schaaf RJ, Adriaenssens T, Koolen JJ, Smits PC, Henriques JP, Vermeersch PH, Tjon Joe Gin RM, Schölzel BE, Kelder JC, Tijssen JG, Agostoni P, Suttorp MJ. Journal: JACC Cardiovasc Interv; 2017 Jan 23; 10(2):133-143. PubMed ID: 28104206. Abstract: OBJECTIVES: The aim of this study was to investigate the efficacy and safety of the hybrid ultrathin-strut sirolimus-eluting stent (SES) with biodegradable polymer compared with the thin-strut everolimus-eluting stent (EES) with durable polymer in successfully recanalized chronic total occlusions (CTOs). BACKGROUND: The introduction of drug-eluting stents revolutionized the treatment of CTOs. However, limited data are available on new-generation drug-eluting stents with biodegradable polymer in CTOs. METHODS: In this multicenter trial, patients were randomized, after successful CTO recanalization, to either SES or EES. The primary noninferiority endpoint was in-segment late lumen loss (noninferiority margin 0.2 mm). Secondary endpoints included in-stent late lumen loss and clinical endpoints. RESULTS: Overall, 330 patients were included. At 9 months, angiography was available in 281 patients (85%). Duration of occlusion ≥3 months was 92.5%, with mean stent length of 52.4 ± 28.1 mm versus 52.3 ± 26.5 mm in the SES and EES groups. The primary noninferiority endpoint, in-segment late lumen loss, was not met for SES versus EES (0.13 ± 0.63 mm vs. 0.02 ± 0.47 mm; p = 0.08, 2-sided; difference 0.11 mm; 95% confidence interval: -0.01 to 0.25 mm; pnoninferiority = 0.11, 1-sided). In-stent late lumen loss was comparable between SES and EES (0.12 ± 0.59 mm vs. 0.07 ± 0.46 mm; p = 0.52). The incidence of in-stent and in-segment binary restenosis was significantly higher with SES compared with EES (8.0% vs. 2.1%; p = 0.028), with comparable rates of reocclusions (2.2% vs. 1.4%; p = 0.68). Clinically indicated target lesion and target vessel revascularization (9.2% vs. 4.0% [p = 0.08] and 9.2% vs. 6.0% [p = 0.33]), target vessel failure (9.9% vs. 6.6%; p = 0.35), and definite or probable stent thrombosis (0.7% vs. 0.7%; p = 1.00) were comparable between the SES and EES groups. CONCLUSIONS: This randomized trial failed to show noninferiority of hybrid SES relative to EES in terms of in-segment late lumen loss in successfully recanalized CTOs. Furthermore, a statistically significantly higher rate of binary restenosis was found with SES.[Abstract] [Full Text] [Related] [New Search]