These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Radial versus femoral access for coronary angiography and intervention is associated with lower patient radiation exposure in high-radial-volume centres: Insights from the RAY'ACT-1 study. Author: Georges JL, Belle L, Meunier L, Dechery T, Khalifé K, Pecheux M, Elhaddad S, Amabile N, Pansieri M, Ballout J, Marchand X, Rouault G, Leddet P, Nugue O, Lucke N, Cattan S, RAY’ACT InvestigatorsCollège National des Cardiologues des Hôpitaux, Société Française de Cardiologie, 75011 Paris, France.. Journal: Arch Cardiovasc Dis; 2017 Mar; 110(3):179-187. PubMed ID: 28117244. Abstract: BACKGROUND: Literature suggests that radial access is associated with higher radiation doses than femoral access. AIMS: To compare patient radiation exposure during coronary angiography (CA) and percutaneous coronary intervention (PCI) with radial versus femoral access. METHODS: RAY'ACT is a nationwide, multicentre, French survey evaluating patient radiation in interventional cardiology. Variables of patient exposure from 21,675 CAs and 17,109 PCIs performed at 44 centres during 2010 were analysed retrospectively. RESULTS: Radial access was used in 71% of CAs and 69% of PCIs. Although median fluoroscopy times were longer for radial versus femoral access (CA, 3.8 vs 3.5minutes [P<0.001]; PCI, 10.4 vs 10.1minutes [P=0.001]), the Kerma-area product (KAP) was lower with radial access (CA, 26.8 vs 28.1Gy·cm2; PCI, 55.6 vs 59.4Gy·cm2; both P=0.001). Differences in KAP remained significant in the multivariable analysis (P<0.01), and in a propensity score-matched analysis (P=0.01). A significant interaction was found between KAP and the percentage of procedures with radial access by centre (P<0.001). KAP was higher by radial versus femoral access in low-radial-volume centres, and lower in high-radial-volume centres. Radiation protection techniques, such as the use of low frame rates (7.5 frame/s), were used more frequently in high-radial-volume radial centres. CONCLUSIONS: In this multicentre study, radial access was associated with lower radiation doses to patient than femoral access in high-radial-volume centres. Provided that radioprotection methods are implemented, radial access could be associated with lower patient radiation exposure.[Abstract] [Full Text] [Related] [New Search]