These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Rapid, sensitive, and reusable detection of glucose by highly monodisperse nickel nanoparticles decorated functionalized multi-walled carbon nanotubes.
    Author: Başkaya G, Yıldız Y, Savk A, Okyay TO, Eriş S, Sert H, Şen F.
    Journal: Biosens Bioelectron; 2017 May 15; 91():728-733. PubMed ID: 28129630.
    Abstract:
    Addressed herein, functionalized multi-walled carbon nanotube (MWCNT) supported highly monodisperse nickel nanoparticles modified on glassy carbon electrode (Ni@f-MWCNT/GCE) were synthesized through microwave assisted method and examined for non-enzymatic glucose sensing in ionic liquids by cyclic voltammetry and chronoamperometry. The results of Ni@f-MWCNT/GCE electrode were compared with Ni NPs/GCE electrode and the results revealed that f-MWCNTs increased the electrocatalytic properties of Ni nanoparticles regarding glucose oxidation. They also demonstrated a good linear span of 0.05-12.0mM and a detection boundary of 0.021µM. Specifically, in the amperometric signal of the electrodes after 200th cycles, no major change was observed. This non-enzymatic glucose sensor presents one of the record electrocatalytic activity, stability and response towards glucose under the optimized situations. As a result, prepared novel Ni@f-MWCNT/GCE was utilized to detect glucose in real serum species.
    [Abstract] [Full Text] [Related] [New Search]