These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Improvement of image quality and dose management in CT fluoroscopy by iterative 3D image reconstruction.
    Author: Grosser OS, Wybranski C, Kupitz D, Powerski M, Mohnike K, Pech M, Amthauer H, Ricke J.
    Journal: Eur Radiol; 2017 Sep; 27(9):3625-3634. PubMed ID: 28168371.
    Abstract:
    OBJECTIVES: The objective of this study was to assess the influence of an iterative CT reconstruction algorithm (IA), newly available for CT-fluoroscopy (CTF), on image noise, readers' confidence and effective dose compared to filtered back projection (FBP). METHODS: Data from 165 patients (FBP/IA = 82/74) with CTF in the thorax, abdomen and pelvis were included. Noise was analysed in a large-diameter vessel. The impact of reconstruction and variables (e.g. X-ray tube current I) influencing noise and effective dose were analysed by ANOVA and a pairwise t-test with Bonferroni-Holm correction. Noise and readers' confidence were evaluated by three readers. RESULTS: Noise was significantly influenced by reconstruction, I, body region and circumference (all p ≤ 0.0002). IA reduced the noise significantly compared to FBP (p = 0.02). The effect varied for body regions and circumferences (p ≤ 0.001). The effective dose was influenced by the reconstruction, body region, interventional procedure and I (all p ≤ 0.02). The inter-rater reliability for noise and readers' confidence was good (W ≥ 0.75, p < 0.0001). Noise and readers' confidence were significantly better in AIDR-3D compared to FBP (p ≤ 0.03). Generally, IA yielded a significant reduction of the median effective dose. CONCLUSION: The CTF reconstruction by IA showed a significant reduction in noise and effective dose while readers' confidence increased. KEY POINTS: • CTF is performed for image guidance in interventional radiology. • Patient exposure was estimated from DLP documented by the CT. • Iterative CT reconstruction is appropriate to reduce image noise in CTF. • Using iterative CT reconstruction, the effective dose was significantly reduced in abdominal interventions.
    [Abstract] [Full Text] [Related] [New Search]