These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Minimum effective fluid volume of colloid to prevent hypotension during caesarean section under spinal anesthesia using a prophylactic phenylephrine infusion: An up-down sequential allocation study.
    Author: Loubert C, Gagnon PO, Fernando R.
    Journal: J Clin Anesth; 2017 Feb; 36():194-200. PubMed ID: 28183565.
    Abstract:
    STUDY OBJECTIVE: The aim of this study was to de termine the minimum effective fluid volume (MEFV) of hydroxyethyl starch 130/0.4 (HES) infused in a preload fashion which would prevent hypotension in 50% of parturients undergoing caesarean section. A secondary objective was to measure the hemodynamic effect of fluid loading on the subjects. DESIGN: This is a prospective, double-blinded, dose-finding study using an up-down sequential allocation design. SETTING: In the operating room. PATIENTS: Thirty healthy parturients undergoing caesarean section under spinal anesthesia using a prophylactic phenylephrine infusion were included in this study. INTERVENTION: The initial HES volume infused in the first patient was 500 mL. A failure of treatment to HES preload was defined as a single episode of systolic hypotension below 20% of baseline value. The next patient in the sequence was given a volume of HES adjusted by either an increment or a decrement of 100 mL according to the previous subject response to fluid preload. MEASUREMENTS: Stroke volume and cardiac output were measured with a bioreactance-based non-invasive cardiac output monitor (NICOM). MAIN RESULTS: The MEFV of HES was 733 mL (95% CI: 388-917 mL). Fluid loading before the administration of the spinal anesthesia resulted in an increase in stroke volume and cardiac output. The combined effect of spinal anesthesia and a phenylephrine infusion reduced the maternal heart rate and cardiac output, but not the stroke volume. CONCLUSION: Our study is the first to investigate variable fluid loading volumes in this population. A HES preload of approximatively 700 mL prevented maternal hypotension in 50% of the parturients under the conditions of this study. We suggest that up-down sequential allocation design is a useful tool to compare different fluid loading regimens in this setting.
    [Abstract] [Full Text] [Related] [New Search]