These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Quantitative measurement of endotoxin in canine plasma using the new endotoxin-specific chromogenic test.
    Author: Ikeda T, Hirata K, Tabuchi K, Tamura H, Tanaka S.
    Journal: Circ Shock; 1987; 23(4):263-9. PubMed ID: 2826038.
    Abstract:
    Endospecy (a lyophilized mixture of factor G-free limulus coagulation enzymes and chromogenic substrate, Boc-Leu-Gly-Arg-pNA) coupled with modified perchloric acid (PCA) pretreatment was carried out for the quantitative measurement of endotoxin in canine plasma. The endotoxin recovery from normal canine plasma was 99.9 +/- 7.7% (n = 20). The full recovery of endotoxin illustrated the applicability of the modified PCA pretreatment to the Endospecy in removal of interfering factors in a canine plasma. The normal canine plasma endotoxin level was less than 3.0 pg.ml-1 when Escherichia coli 0111:B4 endotoxin was used as a reference. The canine plasma endotoxin levels were markedly high(1-40 ng.ml-1) at 5 min after intravenous administration of 25 micrograms.Kg-1 (total 150-200 micrograms).
    [Abstract] [Full Text] [Related] [New Search]