These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Sensitive determination of capsaicin in pepper samples using a voltammetric platform based on carbon nanotubes and ruthenium nanoparticles. Author: Baytak AK, Aslanoglu M. Journal: Food Chem; 2017 Aug 01; 228():152-157. PubMed ID: 28317708. Abstract: A voltammetric platform based on modifying glassy carbon electrodes (GCEs) with ruthenium nanoparticles decorated carbon nanotubes (CNTs) was applied for the determination of capsaicin in pepper samples. The nanoparticles of ruthenium (RuNPs) were obtained at carbon nanotubes modified GCE by cyclic voltammetry. The composite of RuNPs-CNTs was characterized by scanning electron microscopy (SEM) and energy dispersive X-ray (EDX). The proposed voltammetric platform, RuNPs/CNTs/GCE, highly improved the voltammetric process of capsaicin in comparison to the CNTs/GCE and bare GCE. A linear concentration range was obtained from 1.0×10-8 to 4.1×10-7M (R2=0.9987) with a detection limit of 2.5×10-9M. The voltammetric platform has successfully been applied for quantifying capsaicin in various pepper samples including Isot. The proposed voltammetric platform offers advantages such as high sensitivity, selectivity and precision.[Abstract] [Full Text] [Related] [New Search]