These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: [Individual difference of coronal bowing of femur and its influence on the lower limbs alignment after the total knee arthroplasty]. Author: Wu W, Guo WS, Cheng LM, Liu ZH, Zhang QD, Zhang NF. Journal: Zhonghua Yi Xue Za Zhi; 2017 Apr 04; 97(13):1006-1010. PubMed ID: 28395419. Abstract: Objective: To disclose the correlation between the femur bowing angle(FBA) and vulgas correction angle(VCA), anlysys its influence on the total knee arthroplasty and the lower limbs alignment. Methods: From Janurary 2013 to December 2015, 699 patients who had received total knee arthroplasty(TKA)were collected in the Department of Joint Surgery, China-Japan Friendship. The FBA, VCA, offset of the proximal femur, the lengh of the femur, the neck shaft angle of the femur of the eligible cases from the long leg X-ray were measured.All the data were analysed for the following steps: the FBA's mean value and characteristics of distributation of all the cases; the VCA's mean value and characteristics of distributation of all the cases; correlations between the VCA and the other parameters; divide all the cases into four groups based on the value of FBA : group A(FBA<-3°, 29), group B(-3°≤FBA≤0°, 255), group C(0°<FBA≤3°, 480), group D(FBA>3°, 236)and then plan to cut the distal femur with 5° and 6°, respectively. The percent of ideal alignmental outcome's percentage of every group were compared. Results: The mean Value of the FBA is -7.1--12.1(1.4±2.4)°; the mean Value of the VCA is 2.5--11.9(6.5±1.3)°. The correlation index between VCA and FBA, the neck shaft angle of the femur , offset of the hip joint, the lengh of the femur is 0.72, -0.26, 0.45 and -0.08, perspectively. The theoretical ideal alignment percentage of the 5 degree-valgus-bone cut and 6 degree-valgus-bone cut in every group is group A: 89.7% and 66.5%; group B: 93.7% and 95.7%; group C: 71.9% and 94.6%; group D: 21.2% and 50.8%, respectively. Conclusion: The cases whose femur bowing angles are outliers are common in daily medical practice, so the vulgas correction angles need be ajusted for its significant correlation with FBA. 5 degree-valgus-bone cut or 6 degree-valgus-bone cut could not get the ideal alignment some times. 目的:探讨股骨侧弓角(FBA)对全膝人工关节置换术(TKA)术后下肢力线的影响。方法:收集自2013年1月至2015年12月间中日友好医院骨关节外科就诊的接受TKA术前的病例,按照统一标准,筛选出符合入选标准的病例699例1 000膝,在其标准正位下肢全长X线像测量股骨外翻角(VCA),FBA,股骨近端偏心距,股骨长度,股骨颈干角,通过对TKA术前患者下肢全长X线像FBA及VCA等数据的测量,进行如下分析:病例中FBA的均数及分布特点;VCA的均数及分布特点;分析VCA与其余参数间彼此的相关性;按照FBA大小将病例分为A组(FBA<-3°,29例),B组(-3°≤FBA≤0°,255例),C组(0°<FBA≤3°,480例),D组(FBA>3°,236例)4组,模拟分别按照股骨远端5°,6°外翻截骨时,对比各组的理论力线理想率。结果:测量FBA所得均值为-5.7~10.7°(1.4±2.4)°;VCA值为2.5~11.9°(6.5±1.3)°,二者为显著正相关(r=0.72,P<0.05);而颈干角,偏心距和股骨长度与股骨VCA的相关系数分别为-0.26,0.45和-0.08;通过理论截骨后股骨力线理想率A组为5°截骨89.7%,6°截骨66.5%;B组为5°截骨93.7%,6°截骨95.7%;C组为5°截骨71.9%,6°截骨94.6%;而D组为5°截骨21.2%,6°截骨50.8%。结论: TKA术前患者中FBA变化范围较大,由于其与VCA的显著正相关性,FBA变化时,TKA术中股骨远端截骨角度应相应调整才能获得满意的术后下肢力线,常规的股骨5°或6°外翻截骨有时难以获得理想的下肢力线。.[Abstract] [Full Text] [Related] [New Search]