These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: A Simple Measure to Assess Hyperinflation and Air Trapping: 1-Forced Expiratory Volume in Three Second / Forced Vital Capacity. Author: Börekçi S, Demir T, Görek Dilektaşlı A, Uygun M, Yıldırım N. Journal: Balkan Med J; 2017 Apr 05; 34(2):113-118. PubMed ID: 28418337. Abstract: BACKGROUND: Several recent studies have suggested that 1 minus-forced expiratory volume expired in 3 seconds / forced vital capacity (1-FEV3/FVC) may be an indicator of distal airway obstruction and a promising measure to evaluate small airways dysfunction. AIMS: To investigate the associations of 1-FEV3/FVC with the spirometric measures and lung volumes that assess small airways dysfunction and reflects hyperinflation and air trapping. STUDY DESIGN: Retrospective cross-sectional study. METHODS: Retrospective assessment of a total of 1110 cases who underwent body plethysmographic lung volume estimations between a time span from 2005 to 2012. Patients were assigned into two groups: firstly by FEV1/FVC (FEV1/FVC <70% vs. FEV1/FVC ≥70%); secondly by FEV3/FVC < lower limits of normal (LLN) (FEV3/FVC < LLN vs. FEV3/FVC ≥ LLN). Spirometric indices and lung volumes measured by whole-body plethysmography were compared in groups. Also the correlation of spirometric indices with measured lung volumes were assessed in the whole-study population and in subgroups stratified according to FEV1/FVC and FEV3/FVC. RESULTS: Six hundred seven (54.7%) were male and 503 (45.3%) were female, with a mean age of 52.5±15.6 years. Mean FEV3/FVC and 1-FEV3/FVC were 87.05%, 12.95%, respectively. The mean 1-FEV3/FVC was 4.9% in the FEV1/FVC ≥70% group (n=644) vs. 24.1% in the FEV1/FVC <70% group (n=466). A positive correlation was found between 1-FEV3/FVC and residual volume (r=0.70; p<0.0001), functional residual capacity-pleth (r=0.61; p<0.0001), and total lung capacity (r=0.47; p<0.0001). 1-FEV3/FVC was negatively correlated with forced expiratory flow25-75 (r=-0.84; p<0.0001). The upper limit of 95% confidence interval for 1-FEV3/FVC was 13.7%. 1-FEV3/FVC showed significant correlations with parameters of air trapping and hyperinflation measured by whole-body plethysmography. Importantly, these correlations were higher in study participants with FEV1/FVC <70% or FEV3/FVC < LLN compared to those with FEV1/FVC ≥70% or FEV3/FVC ≥ LLN, respectively. CONCLUSION: 1-FEV3/FVC can be easily calculated from routine spirometric measurements. 1-FEV3/FVC is a promising marker of air trapping and hyperinflation. We suggest that 1-FEV3/FVC is complementary to FEV1/FVC and recommend clinicians to routinely report and evaluate together with FEV1/FVC during spirometry.[Abstract] [Full Text] [Related] [New Search]