These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Target analysis of tert-butyldimethylsilyl derivatives of nerve agent hydrolysis products by selectable one-dimensional or two-dimensional gas chromatography-mass spectrometry.
    Author: Seto Y, Tachikawa M, Kanamori-Kataoka M, Sasamoto K, Ochiai N.
    Journal: J Chromatogr A; 2017 Jun 09; 1501():99-106. PubMed ID: 28434709.
    Abstract:
    A target analysis method for the sensitive and discriminative determination of the nerve agent hydrolysis products alkyl methylphosphonic acids as their tert-butyldimethylsilyl (TBDMS) derivatives was developed using a combination of selectable one- and two-dimensional (1D/2D) GC-MS, and applied to the analysis of samples with significant interfering matrices. After sample drying, the alkylmethylphosphonic acids and methylphosphonic acid (MPA) were converted to TBDMS derivatives by addition of N-methyl-N-(tert-butyldimethylsilyl)trifluoroacetamide with heating, and subjected to 1D/2D GC-MS. The apparatus consisted of an initial low thermal mass DB-5 column and a second DB-17 column together with an electron ionization quadrupole mass spectrometer, offering simple and flexible switching between one- and two-dimensional GC-MS analysis in a single GC-MS system. Using 1D/2D GC-MS, analytes that do not co-elute with matrix components can be separated using 1D GC mode alone. Only those parts of the chromatogram that are negatively affected by the co-elution of matrix components need to be transferred and separated with 2D GC. Quantitation can be performed by a combination of both separations and mass spectrometric detection. The TBDMS derivatives of ethyl-, isopropyl-, isobutyl-, pinacolyl-, and cyclohexyl-MPA (cHMPA) and MPA itself were well separated within 3min and determined in 1D GC-MS mode with detection limits of around 10ng/ml of reaction mixture (except for the cHMPA derivative, whose mass spectrum contained noisy background peaks). In 2D-GC-MS mode, where each 0.04min elution window from the 1D GC was subjected to heart-cut (H/C) and transferred to the second column after back-flushing the first column, the peak for the cHMPA TBDMS derivative was isolated and afforded a clean mass spectrum within 6min. The recoveries of all the derivatives on 2D GC from 1D GC were estimated to be over 66%, and the detection limits were around 10ng/ml of reaction mixture. In the presence of urine extract, the target compounds were not detected as separated peaks in 1D GC-MS mode (except for isobutyl-MPA), and quantification based on extracted ion monitoring could not be achieved. However, 2D GC-MS of the H/C fractions of the target derivatives gave single peaks with well-defined mass spectra, and the recoveries of the derivatives were over 70% except for cHMPA (31% at 1.25μg/ml). Phosphonic acids could be detected at less than 60ng/ml. Sulfuric acid and phosphoric acid also negatively affected the determination of alkyl methylphosphonic acid TBDMS derivatives in 1D GC-MS, and the MPA-TBDMS-derivative peak was completely obscured by the large sulfuric-acid-derivative peak. However, under 1D/2D GC-MS conditions, baseline separation of the MPA derivative and sulfuric acid derivative was achieved, enabling highly sensitive MPA detection at 20ng/ml.
    [Abstract] [Full Text] [Related] [New Search]