These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Suture Choice in Lumbar Dural Closure Contributes to Variation in Leak Pressures: Experimental Model. Author: Ghobrial GM, Maulucci CM, Viereck MJ, Beygi S, Chitale A, Prasad S, Jallo J, Heller J, Sharan AD, Harrop JS. Journal: Clin Spine Surg; 2017 Jul; 30(6):272-275. PubMed ID: 28632550. Abstract: STUDY DESIGN: Open-label laboratory investigational study; non-animal surgical simulation. OBJECTIVE: The authors perform a comparison of dural closure strength in a durotomy simulator across 2 different suture materials. SUMMARY OF BACKGROUND DATA: Incidental durotomy leading to persistent cerebrospinal fluid leak adds considerable morbidity to spinal procedures, often complicating routine elective lumbar spinal procedures. Using an experimental durotomy simulation, the authors compare the strength of closure using Gore-Tex with other suture types and sizes, using various closure techniques. METHODS: A comparison of dural closures was performed through an analysis of the peak pressure at which leakage occurred from a standardized durotomy closure in an established cerebrospinal fluid repair model with a premade L3 laminectomy. Nurolon was compared with Gore-Tex sutures sizes (for Gore-Tex, CV-6/5-0 and CV-5/4-0 was compared with Nurolon 4-0, 5-0, and 6-0). RESULTS: Thirty-six trials were performed with Nurolon 4-0, 5-0, and 6-0, whereas 21 trials were performed for 4-0 and 5-0 Gore-Tex. The mean peak pressure at which fluid leakage was observed was 21 cm H2O for Nurolon and 34 cm H2O for Gore-Tex. Irrespective of suture choice, all trials were grouped by closure technique: running suture, locked continuous, and interrupted suture. No significant difference was noted between the groups. For each of the 3 trials groups by closure technique, running, locked continuous, and interrupted, Gore-Tex closures had a significantly higher peak pressure to failure. Interrupted Gore-Tex was significantly higher than Interrupted Nurolon (P=0.007), running Gore-Tex was significantly higher than running Nurolon (P=0.034), and locked Gore-Tex was significantly higher than locked Nurolon (P=0.014). CONCLUSIONS: Durotomy closure in the lumbar spine with Gore-Tex suture may be a reasonable option for providing a watertight closure. In this laboratory study, Gore-Tex suture provided watertight dural closures that withstood higher peak pressures.[Abstract] [Full Text] [Related] [New Search]