These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Improved assessment of mediastinal and pulmonary pathologies in combined staging CT examinations using a fast-speed acquisition dual-source CT protocol.
    Author: Braun FM, Holzner V, Meinel FG, Armbruster M, Brandlhuber M, Ertl-Wagner B, Sommer WH.
    Journal: Eur Radiol; 2017 Dec; 27(12):4931-4940. PubMed ID: 28677055.
    Abstract:
    OBJECTIVES: To demonstrate the feasibility of fast Dual-Source CT (DSCT) and to evaluate the clinical utility in chest/abdomen/pelvis staging CT studies. METHODS: 45 cancer patients with two follow-up combined chest/abdomen/pelvis staging CT examinations (maximally ±10 kV difference in tube potential) were included. The first scan had to be performed with our standard protocol (fixed pitch 0.6), the second one using a novel fast-speed DSCT protocol (fixed pitch 1.55). Effective doses (ED) were calculated, noise measurements performed. Scan times were compared, motion artefacts and the diagnostic confidence rated in consensus reading. RESULTS: ED for the standard and fast-speed scans was 9.1 (7.0-11.1) mSv and 9.2 (7.4-12.8) mSv, respectively (P = 0.075). Image noise was comparable (abdomen; all P > 0.05) or reduced for fast-speed CTs (trachea, P = 0.001; ascending aorta, P < 0.001). Motion artefacts of the heart/the ascending aorta (all P < 0.001) and breathing artefacts (P < 0.031) were reduced in fast DSCT. The diagnostic confidence for the evaluation of mediastinal (P < 0.001) and pulmonary (P = 0.008) pathologies was improved for fast DSCT. CONCLUSIONS: Fast DSCT for chest/abdomen/pelvis staging CT examinations is performed within 2 seconds scan time and eliminates relevant intrathoracic motion/breathing artefacts. Mediastinal/pulmonary pathologies can thus be assessed with high diagnostic confidence. Abdominal image quality remains excellent. KEY POINTS: • Fast dual-source CT provides chest/abdomen/pelvis staging examinations within 2 seconds scan time. • The sevenfold scan time reduction eliminates relevant intrathoracic motion/breathing artefacts. • Mediastinal/pulmonary pathologies can now be assessed with high diagnostic confidence. • The coverage of the peripheral soft tissues is comparable to single-source CT. • Fast and large-volume oncologic DSCT can be performed with 9 mSv effective dose.
    [Abstract] [Full Text] [Related] [New Search]