These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: EVALUATION OF THE I-STAT PORTABLE CLINICAL ANALYZER FOR MEASUREMENT OF IONIZED CALCIUM AND SELECTED BLOOD CHEMISTRY VALUES IN ASIAN ELEPHANTS (ELEPHAS MAXIMUS). Author: Tarbert DK, Behling-Kelly E, Priest H, Childs-Sanford S. Journal: J Zoo Wildl Med; 2017 Jun; 48(2):319-327. PubMed ID: 28749274. Abstract: Thei-STAT® portable clinical analyzer (PCA) provides patient-side results for hematologic, biochemical, and blood gas values when immediate results are desired. This analyzer is commonly used in nondomestic animals; however, validation of this method in comparison with traditional benchtop methods should be performed for each species. In this study, the i-STAT PCA was compared with the Radiometer ABL 800 Flex benchtop analyzer using 24 heparinized whole blood samples obtained from healthy E. maximus . In addition, the effect of sample storage was evaluated on the i-STAT PCA. Analytes evaluated were hydrogen ion concentration (pH), glucose, potassium (K+), sodium (Na+), bicarbonate (HCO3-), total carbon dioxide (TCO2), partial pressure of carbon dioxide (PCO2), and ionized calcium (iCa2+). Statistical analysis using correlation coefficients, Passing-Bablok regression analysis, and Bland-Altman plots found good agreement between results from samples run immediately after phlebotomy and 4 hr postsampling on the i-STAT PCA with the exception of K+, which is known to change with sample storage. Comparison of the results from the two analyzers at 4 hr postsampling found very strong or strong correlation in all values except K+, with statistically significant bias in all values except glucose and PCO2. Despite bias, mean differences assessed via Bland-Altman plots were clinically acceptable for all analytes excluding K+. Within the reference range for iCa2+, the iCa2+ values obtained by the i-STAT PCA and Radiometer ABL 800 Flex were close in value, however in light of the constant and proportionate biases detected, overestimation at higher values and underestimation at lower values of iCa2+ by the i-STAT PCA would be of potential concern. This study supports the use of the i-STAT PCA for the evaluation of these analytes, with the exception of K+, in the Asian elephant.[Abstract] [Full Text] [Related] [New Search]