These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Temperature-Controlled Radiofrequency Ablation for Pulmonary Vein Isolation in Patients With Atrial Fibrillation. Author: Iwasawa J, Koruth JS, Petru J, Dujka L, Kralovec S, Mzourkova K, Dukkipati SR, Neuzil P, Reddy VY. Journal: J Am Coll Cardiol; 2017 Aug 01; 70(5):542-553. PubMed ID: 28750697. Abstract: BACKGROUND: Saline irrigation improved the safety of radiofrequency (RF) ablation, but the thermal feedback for energy titration is absent. OBJECTIVES: To allow temperature-controlled irrigated ablation, a novel irrigated RF catheter was designed with a diamond-embedded tip (for rapid cooling) and 6 surface thermocouples to reflect tissue temperature. High-resolution electrograms (EGMs) from the split-tip electrode allowed rapid lesion assessment. The authors evaluated the preclinical and clinical performance of this catheter for pulmonary vein (PV) isolation. METHODS: Using the DiamondTemp (DT) catheter, pigs (n = 6) underwent discrete atrial ablation in a temperature control mode (60°C/50 W) until there was ∼80% EGM amplitude reduction. In a single-center clinical feasibility study, 35 patients underwent PV isolation with the DT catheter (study group); patients were planned for PV remapping after 3 months, regardless of symptomatology. A control group included 35 patients who underwent PV isolation with a standard force-sensing catheter. RESULTS: Porcine lesion histology revealed transmurality in 51 of 55 lesions (92.7%). In patients, all PVs were successfully isolated; no char or thrombus formation was observed. Compared with the control group, the study cohort had shorter mean RF application duration (26.3 ± 5.2 min vs. 89.2 ± 27.2 min; p < 0.001), shorter mean fluoroscopic time (11.2 ± 8.5 min vs. 19.5 ± 6.8 min; p < 0.001), and lower acute dormant PV reconduction (0 of 35 vs. 5 of 35; p = 0.024). At 3 months, 23 patients underwent remapping: 39 of 46 PV pairs (84.8%) remained durably isolated in 17 of these patients (73.9%). CONCLUSIONS: This first-in-human series demonstrated that temperature-controlled irrigated ablation produced rapid, efficient, and durable PV isolation. (ACT DiamondTemp Temperature-Controlled and Contact Sensing RF Ablation Clinical Trial for Atrial Fibrillation [TRAC-AF]; NCT02821351).[Abstract] [Full Text] [Related] [New Search]