These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Guided growth for angular correction in children: a comparison of two tension band plate designs.
    Author: Kadhim M, Gauthier L, Logan K, El-Hawary R, Orlik B.
    Journal: J Pediatr Orthop B; 2018 Jan; 27(1):1-7. PubMed ID: 28799981.
    Abstract:
    UNLABELLED: This retrospective cohort study examined 20 patients (48 physes), 11 boys and nine girls, who were treated with hinge-plate or eight-plate. The mean age of the patients at surgery was 11.9±2.6 years. The mean follow-up duration was 13±2.7 months. The radiographic measurement of both distal femoral and proximal tibial deformity showed significant correction, with no difference between the hinge-plate and the eight-plate. Both screw divergence angle and the hinge angle showed significant changes at the last follow-up. The deformity correction of the distal femoral physis was quicker than the proximal tibial physis. The rate of mechanical femoral-tibial angle correction was 0.97°/month if both femoral and tibial physes were treated. LEVEL OF EVIDENCE: III.
    [Abstract] [Full Text] [Related] [New Search]