These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Misplaced subclavian central venous catheter.
    Author: Bekele NA, Abebe WA, Shifa JZ.
    Journal: Pan Afr Med J; 2017; 27():59. PubMed ID: 28819481.
    Abstract:
    Percutaneous Central Venous Catheter (CVC) insertion using internal jugular and Subclavian veins routes is common procedure for all intensive care admitted patients and some patients in the ward as demand arises in central and referral hospitals of Botswana. This is a case report of a patient on whom a third attempt of re-inserting a CVC for fluid and total parenteral nutrition (TPN) was made. X-ray showed that left Subclavian inserted catheter was mis-directed to internal jugular vein of the same side creating discomfort to the patient. Ultra sound is recommended for routine investigation to confirm proper Central venous catheter placement as it can reduce failure, minimize complication and reduce cost of treatment.
    [Abstract] [Full Text] [Related] [New Search]