These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Radiographic Tibial Tunnel Assessment After Anterior Cruciate Ligament Reconstruction Using Hamstring Tendon Autografts and Biocomposite Screws: A Prospective Study With 5-Year Follow-Up.
    Author: Karikis I, Ejerhed L, Sernert N, Rostgård-Christensen L, Kartus J.
    Journal: Arthroscopy; 2017 Dec; 33(12):2184-2194. PubMed ID: 28822635.
    Abstract:
    PURPOSE: To radiographically assess the tibial tunnel up to 5 years after anterior cruciate ligament (ACL) reconstruction using hamstring tendon autografts and biocomposite interference screws. METHODS: Fifty-one patients underwent anatomic single-bundle ACL reconstruction with metal interference screws in the femur and biocomposite interference screws in the tibia. Standardized digital radiographs with weight-bearing anteroposterior and lateral views of the index knee were taken in the early postoperative period and at 2 and 5 years postoperatively. Of 51 patients, 40 (78%) underwent radiographic assessment on all 3 occasions. Subjective and objective clinical assessments were obtained preoperatively and at the 5-year follow-up. RESULTS: The mean follow-up period was 65 months (±3.9 months), with a minimum of 59 months. The width of the tibial tunnel on the anteroposterior view was 9.4 mm (±1.4 mm) in the early postoperative period and 9.2 mm (±1.5 mm) at 5 years (P = .64). The corresponding widths on the lateral view were 9.6 mm (±1.5 mm) in the early postoperative period and 9.0 mm (±1.4 mm) at 5 years (P = .014). In 33 of 40 patients (83%) the width of the tibial tunnel had decreased on 1 or both views at 5 years compared with the early postoperative period. The study group had improved significantly at the 5-year follow-up compared with the preoperative assessments in terms of the KT-1000 arthrometer laxity tests (MEDmetric, San Diego, CA), pivot-shift test, Tegner activity scale, and Lysholm knee score (P < .001). No correlations were found between the tunnel widths and the KT-1000 assessment. CONCLUSIONS: In 83% of patients, the width of the tibial tunnel had decreased on 1 or both radiographic views at 5 years compared with the early postoperative period after ACL reconstruction using biocomposite interference screws. LEVEL OF EVIDENCE: Level II, prospective study.
    [Abstract] [Full Text] [Related] [New Search]