These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Safety of coronary CT angiography and functional testing for stable chest pain in the PROMISE trial: A randomized comparison of test complications, incidental findings, and radiation dose. Author: Lu MT, Douglas PS, Udelson JE, Adami E, Ghoshhajra BB, Picard MH, Roberts R, Lee KL, Einstein AJ, Mark DB, Velazquez EJ, Carter W, Ridner M, Al-Khalidi HR, Hoffmann U. Journal: J Cardiovasc Comput Tomogr; 2017; 11(5):373-382. PubMed ID: 28838846. Abstract: BACKGROUND: Coronary computed tomography angiography (CTA) and functional testing strategies for stable chest pain yield similar outcomes; one aspect that may guide test choice is safety. METHODS: We compared test safety (test complications, incidental findings, and effective radiation dose) between CTA and functional testing as-tested in PROMISE (PROspective Multicenter Imaging Study for Evaluation of Chest Pain). In the subgroup whose physicians intended nuclear stress over other functional tests if randomized to the functional arm, we compared radiation dose of CTA versus nuclear stress and identified characteristics associated with dose. RESULTS: Of 9470 patients, none had major and <1% had minor complications (CTA: 0.8% [37/4633] vs. functional: 0.6% [27/4837]). CTA identified more incidental findings (11.6% [539/4633] vs. 0.7% [34/4837], p < 0.001), most commonly pulmonary nodules (9.4%, 437/4633). CTA had similar 90-day cumulative radiation dose to functional testing. However, in the subgroup whose physicians intended nuclear stress (CTA 3147; nuclear 3203), CTA had lower median index test (8.8 vs. 12.6 mSv, p < 0.001) and 90-day cumulative (11.6 vs. 13.1 mSv, p < 0.001) dose, independent of patient characteristics. The lowest nuclear doses employed 1-day Tc-99m protocols (12.2 mSv). The lowest CTA doses were at sites performing ≥500 CTAs/year (6.9 mSv) and with advanced (latest available) CT scanners (5.5 mSv). CONCLUSION: Complications were negligibly rare for both CTA and functional testing. CTA detects more incidental findings. Compared to nuclear stress testing, CTA's lower radiation dose, independent of patient characteristics, makes it an attractive test choice. Radiation dose varies with imaging protocol, indicating opportunities to further reduce dose. (ClinicalTrials.gov number, NCT01174550).[Abstract] [Full Text] [Related] [New Search]