These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Single-center mid-term experience with chimney-graft technique for the preservation of flow to the supra-aortic branches.
    Author: Shahverdyan R, Mylonas S, Gawenda M, Brunkwall J.
    Journal: Vascular; 2018 Apr; 26(2):175-182. PubMed ID: 29022854.
    Abstract:
    Objectives To investigate the feasibility and the mid-term outcomes of the chimney-graft technique for the revascularization of supra-aortic branches in patients with thoracic aortic pathologies involving the aortic arch. Methods A retrospective analysis of a prospectively maintained database between January 2010 and July 2016 was performed. Primary endpoints were 30-day and overall mortality. Secondary endpoints were technical success, target vessel patency, stroke/transitory ischemic attack and type I/III endoleak rate. Results A total of 30 patients (80% male, median age 70.0 years) were treated using the chimney-graft technique for the supra-aortic branches. The indication was a degenerative aneurysm in nine patients (32%) and a type B Stanford aortic dissection and a penetrating aortic ulcer in the descending aorta in seven patients (23%), respectively. In six patients (20.0%), the indication was an type Ia endoleak after previous endovascular thoracic repair, whereas a pseudoaneurysm after previous open repair of the descending aorta was the indication in one patient (3%). Twenty-three patients (77%) were treated electively, five (17%) emergently and two (7%) urgently because of free rupture. Technical success was achieved in 90% of patients. The 30-day/in-hospital mortality was 17% (5/30). A retrograde dissection was presented in five patients. Four patients experienced a cerebrovascular event. Eight patients had type Ia endoleak and 10 had type II. During the median follow-up of 16 months (range: 0-56), four further patients died: one in respiratory insufficiency, one due to a ruptured abdominal aortic aneurysm, one in meningitis and the last one for unknown reason. The chimney-graft patency was 100%. According to the Kaplan-Meier curve, the estimated survival at one year was 66 ± 9%. Conclusions The chimney-graft technique, despite a technically demanding strategy, is a useful tool as bailout procedure in our armamentarium for high-risk patients, unsuitable for open or hybrid repair.
    [Abstract] [Full Text] [Related] [New Search]